Mostrar el registro sencillo del ítem
dc.contributor.author
Sánchez, Gabriela
dc.contributor.author
Calvo, María Lucía
dc.contributor.author
Avalos Ambroggio, Ana Sofia
dc.contributor.author
Gatani, Mariana Pilar
dc.date.available
2021-07-02T15:59:45Z
dc.date.issued
2018-02
dc.identifier.citation
Sánchez, Gabriela; Calvo, María Lucía; Avalos Ambroggio, Ana Sofia; Gatani, Mariana Pilar; Simulación solar y monitoreo del edificio ampliación oeste de la Facultad de Arquitectura, Urbanismo y Diseño de la Universidad Nacional de Córdoba; Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; C&T Des Res Architettura; 2; 2-2018; 1-19
dc.identifier.issn
2525-1147
dc.identifier.uri
http://hdl.handle.net/11336/135417
dc.description.abstract
Este trabajo comprende la primera etapa de la evaluación del desempeño térmico energético del edificio ampliación, ala oeste, de la Facultad de Arquitectura de la Universidad Nacional de Córdoba y constituye un avance de la investigación "Evaluación energética de edificios institucionales. Simulaciones, monitoreo y cálculo de cargas térmicas, demandas y consumos". Consiste en la simulación con el programa Ecotect Analysis del comportamiento del edificio frente al sol, estudios cualitativos y cuantitativos de sombras y obstrucciones, donde se obtuvieron datos de exposición solar, acceso e incidencia solar y máscaras de sombras de las aberturas. Se realizó además el monitoreo de las temperaturas interiores y exteriores y humedad relativa utilizando Hobos Data Logger ubicados en puntos estratégicos del edificio, durante los meses representativos de solsticios y equinoccios, para relevar las condiciones interiores de temperatura. Se compararon los resultados de la simulación con los de monitoreo para obtener conclusiones y evaluar el desempeño del edificio, de sus aberturas y sus protecciones. El análisis del monitoreo del espacio interior arrojó curvas de temperaturas superiores a las exteriores durante todo el año, dando cuenta de espacios muy calurosos en las estaciones verano y primavera. En los resultados alcanzados, se observó que las curvas interiores copian la trayectoria de la curva exterior de temperatura, con muy poco retardo térmico y amortiguación.
dc.description.abstract
This work includes the first stage of the evaluation of the thermal energy performance of the building, west wing, of the Faculty of Architecture of the National University of Cordoba and constitutes an advance of the research "Energy evaluation of institutional buildings. Simulations, monitoring and calculation of thermal loads, demands and consumption ". It consists of the simulation with the program Ecotect Analysis of the behavior of the building in front of the sun, qualitative and quantitative studies of shadows and obstructions, where data of solar exposure, access and solar incidence were obtained and shade masks of the openings. Monitoring of indoor and outdoor temperatures and relative humidity were also performed using the Hobos Data Logger located at strategic points of the building, during the representative months of solstices and equinoxes, to relieve the internal temperature conditions. The results of the simulation and the monitoring were compared to obtain conclusions and evaluate the performance of the building, its openings and its protections. The analysis of the interior space monitoring yielded higher temperature curves than the exteriors throughout the year, giving account of very hot spaces in the summer and spring seasons. In the results obtained, it was observed that the interior curves copied the trajectory of the external curve of temperature, with very little thermal delay and damping.
dc.format
application/pdf
dc.language.iso
spa
dc.publisher
Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-sa/2.5/ar/
dc.subject
SIMULACIÓN
dc.subject
EXPOSICIÓN SOLAR
dc.subject
MASCARAS DE SOMBRAS
dc.subject
MONITOREO
dc.subject.classification
Otras Ingeniería del Medio Ambiente
dc.subject.classification
Ingeniería del Medio Ambiente
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Simulación solar y monitoreo del edificio ampliación oeste de la Facultad de Arquitectura, Urbanismo y Diseño de la Universidad Nacional de Córdoba
dc.title
Solar simulation and monitoring of the west expansion building of the FAUD, UNC
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-06-16T15:14:14Z
dc.journal.number
2
dc.journal.pagination
1-19
dc.journal.pais
Argentina
dc.journal.ciudad
Córdoba
dc.description.fil
Fil: Sánchez, Gabriela. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño; Argentina
dc.description.fil
Fil: Calvo, María Lucía. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño. Centro de Investigaciones Acusticas y Luminotécnicas; Argentina
dc.description.fil
Fil: Avalos Ambroggio, Ana Sofia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba; Argentina. Universidad Nacional de Córdoba. Facultad de Arquitectura, Urbanismo y Diseño. Centro de Investigaciones Acusticas y Luminotécnicas; Argentina
dc.description.fil
Fil: Gatani, Mariana Pilar. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Centro de Investigaciones y Transferencia de Villa María. Universidad Nacional de Villa María. Centro de Investigaciones y Transferencia de Villa María; Argentina
dc.journal.title
C&T Des Res Architettura
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://revistas.unc.edu.ar/index.php/drarchitettura/article/view/18932