dc.identifier.citation
Pellegrini Malpiedi, Luciana; Nerli, Bibiana Beatriz; Taqueda, Maria, E. S.; Abdalla, Dulcineia S. P.; Pessoa Jr., Adalberto; Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems; Elsevier Inc; Protein Expression And Purification; 111; 7-2015; 53-60
dc.identifier.issn
1046-5928
dc.identifier.uri
http://hdl.handle.net/11336/13402
dc.description.abstract
In this work, the purification of a single-chain variable fragment (scFv) of an antibody by using liquid–liquid extraction in aqueous micellar two-phase systems was optimized by means of central composite design. Protein partitioning assays were performed by using the selected system composition in previous works: Triton X-114 at 4% wt/wt, yeast fermentation supernatant at 60% wt/wt, McIlvaine buffer pH 7.00. The other system component concentrations, Cibacron Blue F3GA (CB), Fabsorbent™ F1P HF (HF) and NaCl, were selected as independent variables. ScFv recovery percentage (%R) and purification factor (PF) were selected as the responses. According to the optimization process both, scFv recovery percentage and purification factor were favored with the addition of HF and NaCl in a range of concentrations around the central point of the second central composite design (HF 0.0120% w/w, CB 0.0200% w/w, NaCl 0.200% w/w). These experimental conditions allowed the concentration and pre-purification of scFv in the micelle-rich bottom phase of the systems with a recovery percentage superior to 88% and a purification factor of approximately 3.5. These results improved the previously presented works and demonstrated the convenience of using aqueous micellar two-phase systems as a first step in the purification of scFv molecules.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Inc
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.subject
Antibody Fragments
dc.subject
Aqueous Micellar Two-Phase Systems
dc.subject
Central Composite Design
dc.subject
Surface Response
dc.subject.classification
Otras Ingenierías y Tecnologías
dc.subject.classification
Otras Ingenierías y Tecnologías
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Optimized extraction of a single-chain variable fragment of antibody by using aqueous micellar two-phase systems
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2017-02-24T19:33:14Z
dc.journal.volume
111
dc.journal.pagination
53-60
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Pellegrini Malpiedi, Luciana. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; Argentina
dc.description.fil
Fil: Nerli, Bibiana Beatriz. Consejo Nacional de Investigaciones Cientificas y Tecnicas. Centro Cientifico Tecnol.conicet - Rosario. Instituto de Procesos Biotecnologicos y Quimicos Rosario; Argentina. Universidad Nacional de Rosario; Argentina
dc.description.fil
Fil: Taqueda, Maria, E. S.. Universidade de Sao Paulo; Brasil
dc.description.fil
Fil: Abdalla, Dulcineia S. P.. Universidade de Sao Paulo; Brasil
dc.description.fil
Fil: Pessoa Jr., Adalberto. Universidade de Sao Paulo; Brasil
dc.journal.title
Protein Expression And Purification
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.pep.2015.03.014
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S1046592815000716
Archivos asociados