dc.description.abstract
The electrochemical behavior of polythionine on different electrodes has been investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Polymeric films were obtained by two electropolymerization methods: M1 using cyclic voltammetry or M2 in two steps, a constant potential oxidation and cycle potential sweeps. Those methodologies were compared by analyzing the electrochemical behavior of the films using two redox probes. The modified surfaces were also analyzed as electroanalytical sensors so phenol response was tested and a simple and reliable method for phenol quantification was proposed and validated, corresponding to an M2 glassy carbon modified electrode, using a 0.7 V working potential with a 4 × 10-6 to 2.7 × 10-5 M linear range, with those conditions a 3.6 × 10-6 mol L-1 LOD, 1.09 × 10-5 mol L -1 LOQ and a (2.9 ± 0.2) × 107 C Phenol (mol L-1) sensitivity are obtained.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Pergamon-Elsevier Science Ltd
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
ELECTROPOLYMERIZATION METHODS
dc.subject
PHENOL
dc.subject
POLYTHIONINE
dc.subject.classification
Físico-Química, Ciencia de los Polímeros, Electroquímica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Electrochemical comparison of two methods for polythionineelectropolymerization and its relevance as amperometric detector
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2021-04-23T18:35:43Z
dc.journal.volume
105
dc.journal.pagination
622-628
dc.journal.pais
Estados Unidos
dc.description.fil
Fil: Farias, Eliana Desiree. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
dc.description.fil
Fil: Pfaffen, Maria Valeria del Valle. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
dc.description.fil
Fil: Ortiz, Patricia Ines. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina
dc.journal.title
Electrochimica Acta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0013468613008773
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.electacta.2013.04.163
Archivos asociados