Artículo
Experimentally designed, validated hplc simultaneous determination of pridinol and diclofenac in their combined pharmaceutical formulations, which allows limiting diclofenac related compound A
Fecha de publicación:
01/2010
Editorial:
Taylor & Francis
Revista:
Journal of Liquid Chromatography and Related Technologies
ISSN:
1082-6076
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
The development and validation of an HPLC method for the determination of pridinol and diclofenac in their combined formulations and the simultaneous limit testing of diclofenac related compound A is described. The separation was performed on a C18 column. Experimental design and response surface strategies were employed for optimizing detection wavelength (225nm) and mobile phase composition [MeOH:2-propanol:phosphate buffer (50mM, pH 5.5), 48:9:43 (v/v/v), 1mLmin-1], and for validation purposes. The method was successfully applied to the quality control of commercial brands of tablets and capsules. Found impurity levels were below 0.1% (LOQ=0.02%). Stressed samples were also evaluated.
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos(IQUIR)
Articulos de INST.DE QUIMICA ROSARIO
Articulos de INST.DE QUIMICA ROSARIO
Citación
Vignaduzzo, Silvana Edit; Castellano, Patricia Margarita; Kaufman, Teodoro Saul; Experimentally designed, validated hplc simultaneous determination of pridinol and diclofenac in their combined pharmaceutical formulations, which allows limiting diclofenac related compound A; Taylor & Francis; Journal of Liquid Chromatography and Related Technologies; 33; 19; 1-2010; 1720-1732