Mostrar el registro sencillo del ítem

dc.contributor.author
Yaima, Merchan  
dc.contributor.author
Lucangioli, Silvia Edith  
dc.contributor.author
Carducci, Clyde  
dc.contributor.author
Fajardo, Esther María  
dc.contributor.author
Rico, Jeannete  
dc.contributor.author
Tamayo, Yolexis  
dc.contributor.author
Delgado, Ileana  
dc.date.available
2017-02-13T15:51:23Z  
dc.date.issued
2011-06  
dc.identifier.citation
Yaima, Merchan; Lucangioli, Silvia Edith; Carducci, Clyde; Fajardo, Esther María; Rico, Jeannete; et al.; Determinación de residuos de deoxicolato de sodio en formulaciones vacunales por cromatografía electrocinética micelar; Finlay ediciones; VacciMonitor; 20; 3; 6-2011; 27-33  
dc.identifier.issn
1025-028X  
dc.identifier.uri
http://hdl.handle.net/11336/12908  
dc.description.abstract
El deoxicolato de sodio (DCNa) es el surfactante por excelencia empleado en la industria biofarmacéutica para la solubilización de vesículas de membrana externa. Es bien conocida la importancia que reviste el control de este metabolito en materiales biológicos, debido a su alta toxicidad para el organismo humano. Para demostrar la presencia de bajas concentraciones de este metabolito en formulaciones vacunales es necesario el empleo de una metodología altamente selectiva, sensible, específica y reproducible. En el presente reporte se utilizó la cromatografía electrocinética micelar (MEKC) en un analizador capilar de iones (Water corp. Milford MA), con una detección a 185 nm, con lámpara de mercurio. Se empleó un capilar de sílica fundida (Waters Corp. Milford MA); se evaluó la pureza de dos lotes de deoxicolato de sodio y se analizaron 15 muestras de vesículas purificadas, ingrediente farmacéutico activo de formulaciones vacunales. Los datos fueron registrados y procesados con el software Millennium TM (Waters Corp. Milford MA). Se determinó que los lotes de deoxicolato de sodio contenían 1,19% y 0,44% de ácido cólico contaminante y que el 93% de las muestras de vesículas purificadas tenían de 0 a 2,44 µg DCNa/100 µg de proteína. Los resultados obtenidos por MEKC fueron comparados con una modificación de una prueba cinética empleada para determinar ácidos biliares en sangre (Merckotest). El sistema MEKC mostró mejores resultados con respecto al Merkotest.  
dc.description.abstract
The sodium deoxycholate (DCNa) source is the surfactant used in the biopharmaceutical industry for the solubilization of outer membrane vesicles. It is well known the importance of control of this metabolite in biological materials due to its high toxicity for humans. To demonstrate significant small variations of this metabolite in vaccine formulations it is necessary to use a methodology highly selective, sensitive, specific and reproducible. In this report we used the micellar electrokinetic chromatography (MEKC) in a Capillary Ion Analyzer (Water corp. Milford MA) detection at 185 nm mercury lamp. It employed a fused silica capillary uncoated (Waters Corp. Milford MA). We assessed the purity of 2 lots of sodium deoxycholate and analyzed 15 samples of purified vesicles active pharmaceutical ingredient vaccine formulations. Data were recorded and processed with software Millennium TM (Waters Corp. Milford MA). It was found that lots of sodium deoxycholate containing 1.19 and 0.44% cholic acid and contaminate that 93% of the purified vesicles samples were from 0 to 2.44 mg protein DCNa/100 µg. MECK's results were compared with a kinetic test used to determine bile acids in blood (Merckotest). MECK system showed better results regarding the Merkotest.  
dc.format
application/pdf  
dc.language.iso
spa  
dc.publisher
Finlay ediciones  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Deoxicolato de Sodio  
dc.subject
Mekc  
dc.subject
Vesiculas  
dc.subject
Vacunas  
dc.subject.classification
Otras Ciencias de la Salud  
dc.subject.classification
Ciencias de la Salud  
dc.subject.classification
CIENCIAS MÉDICAS Y DE LA SALUD  
dc.title
Determinación de residuos de deoxicolato de sodio en formulaciones vacunales por cromatografía electrocinética micelar  
dc.title
Determination of Sodium deoxycolate residues in vaccinal formulation by micellar electrokinetic chromatography  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2017-02-09T18:23:32Z  
dc.journal.volume
20  
dc.journal.number
3  
dc.journal.pagination
27-33  
dc.journal.pais
Cuba  
dc.journal.ciudad
La Habana  
dc.description.fil
Fil: Yaima, Merchan. Instituto Finlay; Cuba  
dc.description.fil
Fil: Lucangioli, Silvia Edith. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Houssay; Argentina  
dc.description.fil
Fil: Carducci, Clyde. Universidad de Buenos Aires. Facultad de Farmacia y Bioquímica; Argentina  
dc.description.fil
Fil: Fajardo, Esther María. Instituto Finlay; Cuba  
dc.description.fil
Fil: Rico, Jeannete. Instituto de Nacional Oncología y Radiobiología; Cuba  
dc.description.fil
Fil: Tamayo, Yolexis. Instituto Finlay; Cuba  
dc.description.fil
Fil: Delgado, Ileana. Instituto Finlay; Cuba  
dc.journal.title
VacciMonitor  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://ref.scielo.org/jy5hqp  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.redalyc.org/articulo.oa?id=203420569004