Mostrar el registro sencillo del ítem
dc.contributor.author
Aguirre, María del Carmen
dc.contributor.author
Urreta, Silvia Elena
dc.contributor.author
Gomez, Cesar Gerardo
dc.date.available
2021-03-16T15:43:38Z
dc.date.issued
2019-04
dc.identifier.citation
Aguirre, María del Carmen; Urreta, Silvia Elena; Gomez, Cesar Gerardo; A Cu2+-Cu/glassy carbon system for glyphosate determination; Elsevier Science SA; Sensors and Actuators B: Chemical; 284; 4-2019; 675-683
dc.identifier.issn
0925-4005
dc.identifier.uri
http://hdl.handle.net/11336/128382
dc.description.abstract
Cu° electrocrystallization onto glassy carbon (GC) at potentials between −0.4 V and −0.7 V is consistent with a 3D progressive nucleation mechanism and diffusion-controlled growth. Cu/GC electrode prepared at −0.6 V is applied to the detection of a widely used herbicide such as glyphosate (Glyp). Cyclic voltammetry (CV) and differential pulse voltammetry (DPV) methods are applied in the Glyp determination in acetic acid buffer aqueous solution (ABS) at pH 5 or pH 6. Optimal herbicide detection properties are found for this electrode, arising from Cu°/Cu+ and Cu+/Cu2+ couples. An interesting phenomenon is detected by the DPV method, with Cu/GC electrode in presence of (0.03–0.2 mM) Cu2+ into the ABS at pH 6, when glyphosate is added. For an oxidation potential of −0,015 V vs. Ag/AgCl for Cu°/Cu+ couple (DPV), the current peak is sensitively affected by glyphosate concentration. A strong adsorptive effect between 6 and 30 μM of analyte leads to a linear decrease in the current peak at pH 6. This phenomenon is related to the formation of a barrier of adsorbed glyphosate molecules, which prevent Cu2+ ions diffusion towards the electrode's surface. CVs and DPVs for Cu/GC electrode system in the presence of Glyp and Cu2+ ions are consistent with the transfer of one electron from Cu2+ to Cu+ and from Cu+ to Cu0, which is limited by diffusion of Cu2+ ions. A quantification limit (LOQ) for Glyp of (0.62 ± 0.02) μM [(105 ± 3) μg L–1], and a low determination limit (LOD) of (0.186 ± 0.004) μM (31 (μg L–1) (31g/L)) are obtained from Cu/GC system into ABS pH 6 and 0.1 mM Cu2+ ions. Glyp Determinations for Cu2+-Cu/GC in the presence of interfering cations and in drinking water demonstrated similar sensitivity and stability as in pure systems.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science SA
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights
Atribución-NoComercial-CompartirIgual 2.5 Argentina (CC BY-NC-SA 2.5 AR)
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
CU2+ AND CU/G ELECTRODE
dc.subject
CVS AND DPVS
dc.subject
ELECTROCRYSTALLIZATION MECHANISMS
dc.subject
GLYPHOSATE DETERMINATION
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
A Cu2+-Cu/glassy carbon system for glyphosate determination
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-11-25T16:13:56Z
dc.journal.volume
284
dc.journal.pagination
675-683
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Aguirre, María del Carmen. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina
dc.description.fil
Fil: Urreta, Silvia Elena. Universidad Nacional de Córdoba; Argentina
dc.description.fil
Fil: Gomez, Cesar Gerardo. Universidad Nacional de Córdoba. Instituto de Investigación y Desarrollo en Ingeniería de Procesos y Química Aplicada. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigación y Desarrollo en Ingeniería de Procesos y Química Aplicada; Argentina
dc.journal.title
Sensors and Actuators B: Chemical
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.snb.2018.12.124
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0925400518322433
Archivos asociados