Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Determination of ochratoxin A in coffee and tea samples by coupling second-order multivariate calibration and fluorescence spectroscopy

Gonzalez, Albani L.; Lozano, Valeria AntonellaIcon ; Escandar, Graciela MonicaIcon ; Bravo, Manuel A.
Fecha de publicación: 01/11/2020
Editorial: Elsevier Science
Revista: Talanta
ISSN: 0039-9140
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Química Analítica

Resumen

A new method to quantify the mycotoxin ochratoxin A (OTA) in coffee and tea samples is proposed based on second-order multivariate calibration and excitation-emission fluorescence matrix (EEFM) data. Experimental conditions were optimized by studying the effect of pH and various organized media on the fluorescence signal of OTA. For each analysed matrix (coffee grains and tea leaves), several sample pretreatments and calibration methods (external or standard addition) and data processing by chemometric models (e.g., parallel factor analysis/PARAFAC and multivariate curve resolution-alternating least squares/MCR-ALS) were evaluated and discussed. The MCR-ALS algorithm provided an adequate fit to the data for both samples, while PARAFAC was satisfactory only for the tea samples. Regarding the figures of merit, the limits of detection were in the range of 0.2–0.3 ng mL−1; furthermore, low relative prediction errors, between 2% and 4%, were achieved in both the fortified and real samples. Accordingly, the proposed methodology was applied to analyse fortified roasted and green coffee and real tea leaf samples. Satisfactory recoveries were achieved (ranging from 92 to 110%), and the obtained concentrations were in agreement with the values obtained by the reference method (based on high-performance liquid chromatography with fluorescence detection/HPLC-FLD). In addition, all samples contained OTA levels lower than the maximum permissible levels. Finally, the proposed strategy allows the use of green analytical chemistry principles; for instance, the use of organic solvents and the generation of waste products were significantly lower than for similar analytical methods reported in the literature.
Palabras clave: COFFEE SAMPLES , FLUORESCENCE SPECTROSCOPY , OCHRATOXIN A , SECOND-ORDER MULTIVARIATE CALIBRATION , TEA LEAVES
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.218Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/embargoedAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Atribución-NoComercial-SinDerivadas 2.5 Argentina (CC BY-NC-ND 2.5 AR)
Identificadores
URI: http://hdl.handle.net/11336/127171
URL: https://www.sciencedirect.com/science/article/abs/pii/S0039914020305798
DOI: http://dx.doi.org/10.1016/j.talanta.2020.121288
Colecciones
Articulos(IQUIR)
Articulos de INST.DE QUIMICA ROSARIO
Citación
Gonzalez, Albani L.; Lozano, Valeria Antonella; Escandar, Graciela Monica; Bravo, Manuel A.; Determination of ochratoxin A in coffee and tea samples by coupling second-order multivariate calibration and fluorescence spectroscopy; Elsevier Science; Talanta; 219; 1-11-2020; 1-39; 121288
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES