Mostrar el registro sencillo del ítem

dc.contributor.author
Gutierrez, Fabiana Andrea  
dc.contributor.author
Rubianes, María Dolores  
dc.contributor.author
Rivas, Gustavo Adolfo  
dc.date.available
2021-02-08T20:59:42Z  
dc.date.issued
2019-08  
dc.identifier.citation
Gutierrez, Fabiana Andrea; Rubianes, María Dolores; Rivas, Gustavo Adolfo; New bioanalytical platform based on the use of avidin for the successful exfoliation of multi-walled carbon nanotubes and the robust anchoring of biomolecules. Application for hydrogen peroxide biosensing; Elsevier Science; Analytica Chimica Acta; 1065; 8-2019; 12-20  
dc.identifier.issn
0003-2670  
dc.identifier.uri
http://hdl.handle.net/11336/125145  
dc.description.abstract
We are reporting an innovative building-block for the development of biosensors based on the non-covalent functionalization of multi-walled carbon nanotubes (MWCNTs) with avidin (MWCNTs-avidin). In this work, at variance with previous reports, avidin has the double role of simultaneously being the exfoliating agent of MWCNTs and the platform for anchoring different biotinylated biomolecules. The optimum dispersion was obtained by sonicating for 5.0 min 0.50 mgmL −1 MWCNTs with 1.00 mgmL −1 avidin solution prepared in 50:50 v/v ethanol/water. As proof-of-concept, we immobilized biotinylated horseradish peroxidase (b-HRP) at glassy carbon electrodes (GCE) modified with MWCNTs-avidin to develop a hydrogen peroxide biosensor using hydroquinone as redox mediator. Surface plasmon resonance, electrochemical impedance spectroscopy, cyclic voltammetry and amperometry demonstrated that, even after the partial denaturation of avidin due to the drastic conditions used to functionalize the MWCNTs, it preserves the biorecognition properties and efficiently interacts with biotinylated horseradish peroxidase (b-HRP). The analytical characteristics of the resulting hydrogen peroxide biosensor are the following: linear range between 1.0 × 10 −6 M and 1.4 × 10 −5 M, sensitivity of (1.37 ± 0.04) x 10 5 μAM −1 , detection limit of 24 nM and reproducibility of 2.9%. The sensor was challenged with different samples, a mouthwash solution, human blood serum and milk, with very good performance.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
AVIDIN  
dc.subject
CARBON NANOTUBES FUNCTIONALIZATION  
dc.subject
HORSERADISH PEROXIDASE  
dc.subject
HYDROGEN PEROXIDE BIOSENSOR  
dc.subject
MULTI-WALLED CARBON NANOTUBES  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
New bioanalytical platform based on the use of avidin for the successful exfoliation of multi-walled carbon nanotubes and the robust anchoring of biomolecules. Application for hydrogen peroxide biosensing  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-11-17T18:36:44Z  
dc.journal.volume
1065  
dc.journal.pagination
12-20  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Gutierrez, Fabiana Andrea. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Rubianes, María Dolores. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.journal.title
Analytica Chimica Acta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.aca.2019.03.022  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267019303113