Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

The Low-Dose ACTH Test: Usefulness of Combined Analysis of Serum and Salivary Maximum Cortisol Response in Pediatrics

Vaiani, Elisa; Lazzati, Juan Manuel; Ramirez, Pablo; Costanzo, Mariana; Gil, Silvia; Dratler, Gustavo; Zaidman, Verónica; Chaler, Eduardo Adrian; Belgorosky, AliciaIcon
Fecha de publicación: 10/2019
Editorial: Endocrine Society
Revista: Journal of Clinical Endocrinology and Metabolism
ISSN: 0021-972X
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Endocrinología y Metabolismo

Resumen

Context: The low-dose (1 μg) ACTH test (LDT) is widely used to assess central adrenal insufficiency (CAI); however, the serum cortisol cutoff value is controversial. Salivary cortisol (SC) may be a more accurate measurement for CAI. Objective: To assess a new maximum cutoff value of serum cortisol after LDT in pediatric patients, taking into account serum and SC measurements. Design and Setting: Prospective study in a pediatric tertiary referral center. Working Hypothesis: The combined analysis of serum and SC response to LDT might improve LDT for CAI diagnosis. Participant and Outcome Measurement: A total of 145 pediatric patients underwent LDT. Serum and SC levels were measured. A central adrenal sufficient (CAS) response was established according to the reference serum cortisol cutoff value of ≥497 nmol/L. Results: The LDT study showed central adrenal sufficiency in 72 patients and CAI in 73 patients. Considering the lower quartile of maximum SC value (21 nmol/L) in the CAS group, an intermediate CAI (InCAI) group and a real CAI (RCAI) group were defined. Regarding the median maximum value of serum cortisol levels in the InCAI group, a new serum cortisol cutoff value of 450 nmol/L was established. Furthermore, 91% of the patients in the RCAI group were below this cutoff value. Conclusion: The combined evaluation of maximum serum and SC levels to LDT might be useful to define an InCAI group and to avoid unnecessary hormone replacement therapy. However, rigorous patient follow-up is required © 2019
Palabras clave: Adrenal insufficiency , ACTH , CORTISOL , LDT
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 441.9Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/124448
URL: https://academic.oup.com/jcem/advance-article/doi/10.1210/jc.2019-00304/5498441
DOI: http://dx.doi.org/10.1210/jc.2019-00304
Colecciones
Articulos(SEDE CENTRAL)
Articulos de SEDE CENTRAL
Citación
Vaiani, Elisa; Lazzati, Juan Manuel; Ramirez, Pablo; Costanzo, Mariana; Gil, Silvia; et al.; The Low-Dose ACTH Test: Usefulness of Combined Analysis of Serum and Salivary Maximum Cortisol Response in Pediatrics; Endocrine Society; Journal of Clinical Endocrinology and Metabolism; 104; 10; 10-2019; 4323-4330
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES