Mostrar el registro sencillo del ítem

dc.contributor.author
Acquaro Junior, Vinicius R.  
dc.contributor.author
Goméz-Ríos, Germán Augusto  
dc.contributor.author
Tascon, Marcos  
dc.contributor.author
Costa Queiroz, Maria Eugênia  
dc.contributor.author
Pawliszyn, Janusz  
dc.date.available
2021-01-29T12:28:58Z  
dc.date.issued
2019-09  
dc.identifier.citation
Acquaro Junior, Vinicius R.; Goméz-Ríos, Germán Augusto; Tascon, Marcos; Costa Queiroz, Maria Eugênia; Pawliszyn, Janusz; Analysis of endocannabinoids in plasma samples by biocompatible solid-phase microextraction devices coupled to mass spectrometry; Elsevier Science; Analytica Chimica Acta; 1091; 9-2019; 135-145  
dc.identifier.issn
0003-2670  
dc.identifier.uri
http://hdl.handle.net/11336/124166  
dc.description.abstract
Anandamide (AEA) and 2-arachidonoyl glycerol (2-AG) represent two of the most important endocannabinoids (ECs) investigated in neurobiology as therapeutic targets for several mental disorders. However, the determination of these ECs in biological matrices remains a challenging task because of the low concentrations, low stability and high protein-bound (LogP ∼ 6). This work describes innovative analytical methods based on biocompatible SPME (Bio-SPME), SPME-UHPLC-MS/MS and Bio-SPME-Nano-ESI-MS/MS, to determine AEA and 2-AG in human plasma samples. The direct coupling of Bio-SPME with nano-ESI-MS/MS can be considered an alternative tool for faster analysis. Different Bio-SPME fibers based on silica and polymeric coating (i.e. C18, C30, and HLB) were evaluated. Different desorption solvents based on combinations of methanol, acetonitrile, and isopropanol were also evaluated for efficient elution with minimum carry-over. Given the high protein binding analytes and the fact that SPME extracts the free-concentration of the analytes, the plasma samples were modified with additives such as guanidine hydrochloride (Gu-HCl), trifluoroacetic acid, and acetonitrile. This study was carried out by experimental design to achieve complete protein denaturation and the release of target analytes. The maximum extraction efficiency was obtained under the following conditions: HLB coated fibers (10 mm length, 20 μm coating thickness), matrix modified (300 μL of plasma) with 50 μL of Gu-HCL 1 mol L−1, 75 μL of ACN and 75 μL of water, and desorption with methanol/isopropanol solution (50:50, v/v). Both methods were validated based on current international guidelines and can be applied for monitoring of concentrations of endocannabinoids in plasma samples. SPME-UHPLC-MS/MS method presented lower LOQ values than SPME-nanoESI-MS/MS. The additional separation (chromatographic column) favored the detectability of LC-MS/MS method. However, the SPME-nano-ESI-MS/MS decrease the total analysis time, due to significant reductions in desorption and detection times.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
BIOFLUID  
dc.subject
ENDOCANNABINOIDS  
dc.subject
HUMAN PLASMA  
dc.subject
MS/MS  
dc.subject
NANO-ESI  
dc.subject
SPME  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Analysis of endocannabinoids in plasma samples by biocompatible solid-phase microextraction devices coupled to mass spectrometry  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-11-18T20:12:10Z  
dc.journal.volume
1091  
dc.journal.pagination
135-145  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Acquaro Junior, Vinicius R.. University of Waterloo; Canadá. Universidade de Sao Paulo; Brasil  
dc.description.fil
Fil: Goméz-Ríos, Germán Augusto. University of Waterloo; Canadá  
dc.description.fil
Fil: Tascon, Marcos. University of Waterloo; Canadá. Universidad Nacional de San Martín. Instituto de Investigación e Ingeniería Ambiental. - Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación e Ingeniería Ambiental; Argentina  
dc.description.fil
Fil: Costa Queiroz, Maria Eugênia. Universidade de Sao Paulo; Brasil  
dc.description.fil
Fil: Pawliszyn, Janusz. University of Waterloo; Canadá  
dc.journal.title
Analytica Chimica Acta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.aca.2019.09.002  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0003267019310451