Artículo
Automatic correction of background phase offset in 4D-flow of great vessels and of the heart in MRI using a third-order surface model
Craiem, Damian
; Pascaner, Ariel Fernando
; Casciaro, Mariano Ezequiel
; Gencer, Umit; Alcibar, Joaquin; Soulat, Gilles; Mousseaux, Elie
Fecha de publicación:
12/2019
Editorial:
Springer
Revista:
Magnetic Resonance Materials In Physics Biology And Medicine
ISSN:
0968-5243
Idioma:
Inglés
Tipo de recurso:
Artículo publicado
Clasificación temática:
Resumen
Objective: To evaluate an automatic correction method for velocity offset errors in cardiac 4D-flow acquisitions. Materials and methods: Velocity offset correction was done in a plane-by-plane scheme and compared to a volumetric approach. Stationary regions were automatically detected. In vitro experiments were conducted in a phantom using two orientations and two encoding velocities (Venc). First- to third-order models were fit to the time-averaged images of the three velocity components. In vivo experiments included realistic ROIs in a volunteer superimposed to a phantom. In 15 volunteers, blood flow volume of the proximal and distal descending aorta, of the pulmonary artery (Qp) and the ascending aorta (Qs) was compared. Results: Offset errors were reduced after correction with a third-order model, yielding residual phantom velocities below 0.6 cm/s and 0.4% of Venc. The plane-by-plane correction method was more effective than the volumetric approach. Mean velocities through superimposed ROIs of a volunteer vs phantom were highly correlated (r2 = 0.96). The significant difference between proximal and distal descending aortic flows was decreased after correction from 8.1 to − 1.4 ml (p < 0.001) and Qp/Qs reduced from 1.08 ± 0.09 to 1.01 ± 0.05. Discussion: An automatic third-order model corrected velocity offset errors in 4D-flow acquisitions, achieving acceptable levels for clinical applications.
Palabras clave:
BLOOD FLOW
,
EDDY CURRENTS
,
PHASE-CONTRAST MRI
,
VELOCITY OFFSET ERROR
Archivos asociados
Licencia
Identificadores
Colecciones
Articulos (IMETTYB)
Articulos de INSTITUTO DE MEDICINA TRASLACIONAL, TRASPLANTE Y BIOINGENIERIA
Articulos de INSTITUTO DE MEDICINA TRASLACIONAL, TRASPLANTE Y BIOINGENIERIA
Citación
Craiem, Damian; Pascaner, Ariel Fernando; Casciaro, Mariano Ezequiel; Gencer, Umit; Alcibar, Joaquin; et al.; Automatic correction of background phase offset in 4D-flow of great vessels and of the heart in MRI using a third-order surface model; Springer; Magnetic Resonance Materials In Physics Biology And Medicine; 32; 6; 12-2019; 629-642
Compartir
Altmétricas