Mostrar el registro sencillo del ítem
dc.contributor.author
Linares, L. H.
dc.contributor.author
Guirin, G.
dc.contributor.author
Stambullian, J.
dc.contributor.author
Brusa, V.
dc.contributor.author
de la Torre, J. H.
dc.contributor.author
Ortega, E. E.
dc.contributor.author
Copes, J.
dc.contributor.author
Leotta, Gerardo Anibal
dc.date.available
2017-01-19T21:40:21Z
dc.date.issued
2015-08
dc.identifier.citation
Linares, L. H.; Guirin, G.; Stambullian, J.; Brusa, V.; de la Torre, J. H.; et al.; Evaluación de un producto desinfectante aplicado por micro-nebulización; Universidad Nacional de la Plata. Facultad de Ciencias Veterinarias; Analecta Veterinaria; 35; 1; 8-2015; 13-16
dc.identifier.uri
http://hdl.handle.net/11336/11697
dc.description.abstract
La contaminación ambiental puede representar un problema para la salud pública. El objetivo de este trabajo fue evaluar el poder bactericida de un producto a base de peróxido de hidrógeno y sales de plata aplicado mediante micronebulización. El estudio fue realizado en ambientes con distinta frecuencia de procedimientos operativos estandarizados de sanitización: un aula universitaria y un quirófano. Previo a la aplicación del producto bactericida se colectaron muestras de superficies y aire para recuento de mesófilos. A los 12 min de aplicado el producto se tomaron muestras ambientales para determinar el efecto inmediato. El efecto residual se evaluó hasta 17 h posteriores a la aplicación. En el aula los mayores recuentos iniciales se observaron en la lámpara y pisos. Luego de aplicado el producto los mejores resultados se observaron en el aire mientras que en las superficies los resultados fueron variables. En el quirófano, el mayor desarrollo pretratamiento se detectó en aire y pisos. El efecto inmediato tuvo una eficacia absoluta en todas las muestras excepto en pisos, mientras que el efecto residual arrojó resultados negativos hasta 17 h posteriores. La alternativa evaluada fue eficaz y novedosa. Es interesante desarrollar estos sistemas como herramienta para mejorar la eficiencia del procedimiento operativo estandarizado de sanitización en ambientes controlados a nivel industrial.
dc.description.abstract
Environmental contamination may represent a public health problem. We evaluated the bactericide power of a product containing hydrogen peroxide and silver salts applied by micronebulization in rooms with different frequency of sanitation standard operating procedures: a university classroom and an operating room. Before applying the bactericidal product, surface and air samples were collected for mesophilic count. Environmental samples were collected after 12 min of product application to determine the immediate effect. The residual effect was evaluated up to 17 h after application. In the classroom, the highest initial counts were observed on a lamp and floor. After application of the product, the best results were observed in the air whereas results were variable on the surfaces sampled. In the operating room, pre-treatment counts were higher in the air and floors. The immediate effect was totally efficient in all samples excepting floors, whereas the residual effect showed negative results up to 17 h after application. The alternative tested was effective and novel; therefore, its development would improve the efficiency of sanitation standard operating procedures in industrially controlled environments.
dc.format
application/pdf
dc.language.iso
spa
dc.publisher
Universidad Nacional de la Plata. Facultad de Ciencias Veterinarias
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Peroxido de Hidrogeno
dc.subject
Contaminacion Ambiental
dc.subject
Accion Bactericida
dc.subject.classification
Otras Ciencias Veterinarias
dc.subject.classification
Ciencias Veterinarias
dc.subject.classification
CIENCIAS AGRÍCOLAS
dc.title
Evaluación de un producto desinfectante aplicado por micro-nebulización
dc.title
Evaluation of a Bactericidal Product Applied by Micronebulization
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2017-01-17T19:04:07Z
dc.identifier.eissn
1514-2590
dc.journal.volume
35
dc.journal.number
1
dc.journal.pagination
13-16
dc.journal.pais
Argentina
dc.journal.ciudad
La Plata
dc.description.fil
Fil: Linares, L. H.. Universidad Nacional de La Plata. Facultad de Ciencias Veterinarias; Argentina
dc.description.fil
Fil: Guirin, G.. Universidad Nacional de Lanus; Argentina
dc.description.fil
Fil: Stambullian, J.. Centro De Estudios Infectologicos Dr. Stamboulian; Argentina
dc.description.fil
Fil: Brusa, V.. Universidad Nacional de La Plata. Facultad de Ciencias Veterinarias; Argentina
dc.description.fil
Fil: de la Torre, J. H.. Universidad Nacional de La Plata. Facultad de Ciencias Veterinarias; Argentina
dc.description.fil
Fil: Ortega, E. E.. Universidad Nacional de La Plata. Facultad de Ciencias Veterinarias; Argentina
dc.description.fil
Fil: Copes, J.. Universidad Nacional de La Plata. Facultad de Ciencias Veterinarias; Argentina
dc.description.fil
Fil: Leotta, Gerardo Anibal. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico La Plata. Instituto de Genética Veterinaria "Ingeniero Fernando Noel Dulout"; Argentina. Universidad Nacional de La Plata. Facultad de Ciencias Veterinarias; Argentina
dc.journal.title
Analecta Veterinaria
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.fcv.unlp.edu.ar/images/stories/analecta/vol_35_n1/265_Linares.pdf
Archivos asociados