Mostrar el registro sencillo del ítem

dc.contributor.author
Lozano, María Luisa C.  
dc.contributor.author
Galicia, Laura  
dc.contributor.author
Rodriguez, Marcela Cecilia  
dc.contributor.author
Rivas, Gustavo Adolfo  
dc.date.available
2020-09-11T12:33:33Z  
dc.date.issued
2009-06  
dc.identifier.citation
Lozano, María Luisa C.; Galicia, Laura; Rodriguez, Marcela Cecilia; Rivas, Gustavo Adolfo; Quantification of hydrogen peroxide using poly Fe (III)-5-Amino 1,10 phenantroline; The Electrochemical Society; ECS Transactions; 20; 1; 6-2009; 41-48  
dc.identifier.issn
1938-5862  
dc.identifier.uri
http://hdl.handle.net/11336/113769  
dc.description.abstract
This work reports the results obtained with a composite prepared by dispersing multiple-wall carbon nanotubes in mineral oil (CNTPE) modified with a polymeric matrix of poly Fe(III)-5- Amino 1,10 phenanthroline (MCNTPE). The MCNTPE was used as electrochemical sensor for hydrogen peroxide quantification based on the polymer electrocatalytic effects. The amperometric response to H2O2 on MCNTPE was evaluated at -0,100 and 0,700 V vs Ag/AgCl. At -0,100 V, the sensitivity of the MCNTPE was increased by a factor of 2 orders of magnitude in comparison with the one obtained at CNTPE. At 700 mV, the sensitivity of the modified electrode was increased by a factor of 268 with respect to the non-modified electrode. The sensor also demonstrated to be very stable after continuous use. These results show that a new composite with remarkable electrocatalytic properties can be proposed for the future development of electrochemical (bio)sensors for the quantification of hydrogen peroxide.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
The Electrochemical Society  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Carbon Nanotubes  
dc.subject
Poly Fe(Iii)-5- Amino 1,10 Phenanthroline  
dc.subject
Electrochemical Sensor  
dc.subject
Hydrogen Peroxide  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Quantification of hydrogen peroxide using poly Fe (III)-5-Amino 1,10 phenantroline  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-05-06T13:48:28Z  
dc.identifier.eissn
1938-6737  
dc.journal.volume
20  
dc.journal.number
1  
dc.journal.pagination
41-48  
dc.journal.pais
Estados Unidos  
dc.journal.ciudad
Pennington, NJ  
dc.description.fil
Fil: Lozano, María Luisa C.. Universidad Autónoma Metropolitana; México  
dc.description.fil
Fil: Galicia, Laura. Universidad Autónoma Metropolitana; México  
dc.description.fil
Fil: Rodriguez, Marcela Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.description.fil
Fil: Rivas, Gustavo Adolfo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Investigaciones en Físico-química de Córdoba. Universidad Nacional de Córdoba. Facultad de Ciencias Químicas. Instituto de Investigaciones en Físico-química de Córdoba; Argentina  
dc.journal.title
ECS Transactions  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1149/1.3268371  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://iopscience.iop.org/article/10.1149/1.3268371