Acquaviva, Agustín; Tascon, Marcos; Padro, Juan Manuel; Gagliardi, Leonardo Gabriel; Castells, Cecilia Beatriz Marta; Automatized sspKa measurements of dihydrogen phosphate and Tris(hydroxymethyl) aminomethane in acetonitrile/water mixtures from 20 to 60 ºC; Elsevier Science; Talanta; 127; 9-2014; 196-203
dc.identifier.issn
0039-9140
dc.identifier.uri
http://hdl.handle.net/11336/11219
dc.description.abstract
We measured pKa values of Tris(hydroxymethyl)aminomethane and dihydrogen phosphate; both are commonly used to prepare buffers for reverse-phase liquid chromatography (RPLC), in acetonitrile/water mixtures from 0% to 70% (v/v) (64.6% (w/w)) acetonitrile and at 20, 30, 40, 50, and 60 1C. The procedure is based on potentiometric measurements of pH of buffer solutions of variable solvent compositions using a glass electrode and a novel automated system. The method consists in the controlled additions of small volumes of a thermostated solution from an automatic buret into another isothermal solution containing exactly the same buffer-component concentrations, but a different solvent composition. The continuous changes in the solvent composition induce changes in the potentials. Thus, only two sequences of additions are needed: increasing the amount of acetonitrile from pure water and decreasing the content of acetonitrile from 70% (v/v) (64.6% (w/w)). In the procedure with homemade apparatus, times for additions, stirring, homogenization, and data acquisition are entirely controlled by software programmed for this specific routine. This rapid, fully automated method was applied to acquire more than 40 potential data covering the whole composition range (at each temperature) in about two hours and allowed a systematic study of the effect of temperature and acetonitrile composition on acid–base equilibria of two widely used substances to control pH close to 7. The experimental pKa results were fitted to empirical functions between pKa and temperature and acetonitrile composition. These equations allowed predictions of pKa to estimate the pH of mixtures at any composition and temperature, which would be very useful, for instance, during chromatographic method development.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/
dc.subject
Potentiometric Method
dc.subject
Buffer Pka
dc.subject
Tris(Hydroxymethyl)Aminomethane
dc.subject
Dihydrogen Phosphate
dc.subject
Acetonitrile/Water Mixtures
dc.subject
Temperature
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Automatized sspKa measurements of dihydrogen phosphate and Tris(hydroxymethyl) aminomethane in acetonitrile/water mixtures from 20 to 60 ºC
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2017-01-11T19:18:31Z
dc.journal.volume
127
dc.journal.pagination
196-203
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Acquaviva, Agustín. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación de Métodos Analíticos ; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Tascon, Marcos. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación de Métodos Analíticos ; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Padro, Juan Manuel. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación de Métodos Analíticos ; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Gagliardi, Leonardo Gabriel. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación de Métodos Analíticos ; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Castells, Cecilia Beatriz Marta. Universidad Nacional de La Plata. Facultad de Ciencias Exactas. Laboratorio de Investigación de Métodos Analíticos ; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.journal.title
Talanta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2014.04.018
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0039914014002963
Archivos asociados