Artículo

Model-based cost optimization of double-effect water-lithium bromide absorption refrigeration systems

Mussati, Sergio FabianIcon ; Mansouri, Seyed Soheil; Gernaey, Krist V.; Morosuk, Tatiana; Mussati, Miguel CeferinoIcon
Fecha de publicación: 19/01/2019
Editorial: MDPI
Revista: Processes
ISSN: 2227-9717
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ingeniería Química

Resumen

This work presents optimization results obtained for a double-effect H2O-LiBr absorption refrigeration system considering the total cost as minimization criterion, for a wide range of cooling capacity values. As a model result, the sizes of the process units and the corresponding operating conditions are obtained simultaneously. In this paper, the effectiveness factor of each proposed heat exchanger is considered as a model optimization variable which allows (if beneficial, according to the objective function to be minimized) its deletion from the optimal solution, therefore, helping us to determine the optimal configuration. Several optimization cases considering different target levels of cooling capacity are solved. Among the major results, it was observed that the total cost is considerably reduced when the solution heat exchanger operating at low temperature is deleted compared to the configuration that includes it. Also, it was found that the effect of removing this heat exchanger is comparatively more significant with increasing cooling capacity levels. A reduction of 9.8% in the total cost was obtained for a cooling capacity of 16 kW (11,537.2 $·year-1 vs. 12,794.5 $·year-1), while a reduction of 12% was obtained for a cooling capacity of 100 kW (31,338.1 $·year-1 vs. 35,613.9 $·year-1). The optimization mathematical model presented in this work assists in selecting the optimal process configuration, as well as determining the optimal process unit sizes and operating conditions of refrigeration systems.
Palabras clave: ABSORPTION REFRIGERATION , COST OPTIMIZATION , DOUBLE-EFFECT SYSTEM , H2O-LIBR WORKING PAIR , NONLINEAR MATHEMATICAL PROGRAMMING
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 2.971Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial 2.5 Unported (CC BY-NC 2.5)
Identificadores
URI: http://hdl.handle.net/11336/108977
URL: https://www.mdpi.com/2227-9717/7/1/50
DOI: http://dx.doi.org/10.3390/pr7010050
Colecciones
Articulos(INGAR)
Articulos de INST.DE DESARROLLO Y DISEÑO (I)
Citación
Mussati, Sergio Fabian; Mansouri, Seyed Soheil; Gernaey, Krist V.; Morosuk, Tatiana; Mussati, Miguel Ceferino; Model-based cost optimization of double-effect water-lithium bromide absorption refrigeration systems; MDPI; Processes; 7; 1; 19-1-2019; 1-16
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES