dc.identifier.citation
de Grucci, Carla; Bonell, C. E.; Dutto, César Ignacio; Barrera, Verónica; Bernal, Cecilia; et al.; Gait Analysis through a visual method to calculate temporal parameters: comparison of performance between the gait laboratory and the clinical setting; SABI; Revista Argentina de Bioingeniería; 23; 2; 12-2019; 2-7  
dc.identifier.issn
2591-376X  
dc.identifier.uri
http://hdl.handle.net/11336/107371  
dc.description.abstract
Analysis of human movement providessystematic and quantitative information of movement. The detection of eventsthat occur during walking allows for the calculation of spatiotemporalparameters, commonly used for the characterization of gait. A method for visualdetection of gait events was previously evaluated, showing promising results.The method should now be used in the clinical setting for estimation of gaitparameters and symmetry. The aims of this study were then to compare theperformance of the visual method in a clinical setting against its performancein a gait laboratory and to evaluate its behavior for calculation of gaitsymmetry in eight healthy subjects. Two gait events were detected and sixtemporal parameters (TP) were calculated. Also, a symmetry index (SI) wascalculated for three TP. Results for the calculation of TP in the clinicalsetting were comparable to those obtained in the gait laboratory. Also, thevalues of TP and symmetry were within the range of those reported by otherauthors. These results suggest that the visual events detection method can beconsidered as an option for basic Analysis of Human Movement in the clinicalenvironment.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
SABI  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
CLINICAL SETTING  
dc.subject
EVENT DETECTION  
dc.subject
GAIT ANALYSIS  
dc.subject
TEMPORAL PARAMETERS  
dc.subject
SIMMETRY INDEX  
dc.subject
VIDEOCAMERA  
dc.subject.classification
Ingeniería Médica  
dc.subject.classification
Ingeniería Médica  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Gait Analysis through a visual method to calculate temporal parameters: comparison of performance between the gait laboratory and the clinical setting  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-06-01T13:38:49Z  
dc.journal.volume
23  
dc.journal.number
2  
dc.journal.pagination
2-7  
dc.journal.pais
Argentina  
dc.description.fil
Fil: de Grucci, Carla. Universidad Nacional de Entre Ríos. Facultad de Ingeniería; Argentina  
dc.description.fil
Fil: Bonell, C. E.. Universidad Nacional de Entre Ríos; Argentina  
dc.description.fil
Fil: Dutto, César Ignacio. Hospital Integral del Discapacitado Dr. Vera Candioti; Argentina  
dc.description.fil
Fil: Barrera, Verónica. Hospital Integral del Discapacitado Dr. Vera Candioti; Argentina  
dc.description.fil
Fil: Bernal, Cecilia. Hospital Integral del Discapacitado Dr. Vera Candioti; Argentina  
dc.description.fil
Fil: Catalfamo Formento, Paola Andrea Lucia. Universidad Nacional de Entre Ríos. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática - Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Santa Fe. Instituto de Investigación y Desarrollo en Bioingeniería y Bioinformática; Argentina  
dc.journal.title
Revista Argentina de Bioingeniería  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://revista.sabi.org.ar/index.php/revista/issue/view/15