dc.contributor.author
Colombo, Elisa Margarita

dc.contributor.author
Derrington, Andrew
dc.date.available
2020-05-22T18:54:36Z
dc.date.issued
2001-07
dc.identifier.citation
Colombo, Elisa Margarita; Derrington, Andrew; Visual calibration of CRT monitors; Elsevier Science; Displays; 22; 3; 7-2001; 87-95
dc.identifier.issn
0141-9382
dc.identifier.uri
http://hdl.handle.net/11336/105783
dc.description.abstract
In this paper, we develop and test a technique for calibrating a computer-controlled television monitor using a visual comparison instead of a photometer. The basic principle of the calibration is to compare a patch of pixels that are uniformly driven for an adjustable voltage with a patch in which a predetermined fraction of the pixels are set to the maximum voltage and the remainder are set to the minimum. By adjusting the voltage to make the two patches appear equally bright we get an estimate of the voltage that produces the predetermined fraction of the maximum luminance. Smooth functions were fit to the relationship between the DAC output and the fraction of illuminated pixels using a least-squares method, and used to estimate the function relating screen luminance to voltage. This function was then used to calculate lookup tables for linearisation. Sinusoidal and beat (sum of two sinusoids) luminance modulations were generated from the calibrated lookup tables and their profiles were measured with a photometer in order to check the calibrations. We find that visual calibration is sufficiently reliable to be used as an alternative to calibration using a photometer. It is easier and cheaper than using a photometer: a good photometer can be more expensive than the combined cost of the computer, graphics card and monitor.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science

dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
DISPLAYS NON LINEARITY
dc.subject
CRT MONITORS
dc.subject
PSYCHOPHYSICS
dc.subject
CALIBRATION
dc.subject
VISION
dc.subject.classification
Otras Ingenierías y Tecnologías

dc.subject.classification
Otras Ingenierías y Tecnologías

dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS

dc.title
Visual calibration of CRT monitors
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-04-14T20:56:32Z
dc.journal.volume
22
dc.journal.number
3
dc.journal.pagination
87-95
dc.journal.pais
Países Bajos

dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Colombo, Elisa Margarita. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina
dc.description.fil
Fil: Derrington, Andrew. University or Park; Reino Unido
dc.journal.title
Displays

dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/S0141-9382(01)00055-5
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0141938201000555
Archivos asociados