dc.description.abstract
In this paper, we develop and test a technique for calibrating a computer-controlled television monitor using a visual comparison instead of a photometer. The basic principle of the calibration is to compare a patch of pixels that are uniformly driven for an adjustable voltage with a patch in which a predetermined fraction of the pixels are set to the maximum voltage and the remainder are set to the minimum. By adjusting the voltage to make the two patches appear equally bright we get an estimate of the voltage that produces the predetermined fraction of the maximum luminance. Smooth functions were fit to the relationship between the DAC output and the fraction of illuminated pixels using a least-squares method, and used to estimate the function relating screen luminance to voltage. This function was then used to calculate lookup tables for linearisation. Sinusoidal and beat (sum of two sinusoids) luminance modulations were generated from the calibrated lookup tables and their profiles were measured with a photometer in order to check the calibrations. We find that visual calibration is sufficiently reliable to be used as an alternative to calibration using a photometer. It is easier and cheaper than using a photometer: a good photometer can be more expensive than the combined cost of the computer, graphics card and monitor.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
DISPLAYS NON LINEARITY  
dc.subject
CRT MONITORS  
dc.subject
PSYCHOPHYSICS  
dc.subject
CALIBRATION  
dc.subject
VISION  
dc.subject.classification
Otras Ingenierías y Tecnologías  
dc.subject.classification
Otras Ingenierías y Tecnologías  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Visual calibration of CRT monitors  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-04-14T20:56:32Z  
dc.journal.volume
22  
dc.journal.number
3  
dc.journal.pagination
87-95  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Colombo, Elisa Margarita. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Tucumán. Instituto de Investigación en Luz, Ambiente y Visión. Universidad Nacional de Tucumán. Facultad de Ciencias Exactas y Tecnología. Instituto de Investigación en Luz, Ambiente y Visión; Argentina  
dc.description.fil
Fil: Derrington, Andrew. University or Park; Reino Unido  
dc.journal.title
Displays  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/S0141-9382(01)00055-5  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0141938201000555