Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

De la osteología a la osteomiología: tres décadas de aportes originales continuos al análisis biomecánico osteomuscular

Título: From osteology to osteo-myology: three decades of continuous, original contributions to musculoskeletal biomechanical analysis
Ferretti, Jose LuisIcon ; Cointry, Gustavo RobertoIcon ; Capozza, Ricardo FranciscoIcon
Fecha de publicación: 11/2018
Editorial: Asociación Argentina de Osteología y Metabolismo Mineral
Revista: Actualizaciones en Osteología
ISSN: 1669-8975
e-ISSN: 1669-8983
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Otras Ciencias de la Salud

Resumen

 
En consonancia con la orientación tradicional de nuestras investigaciones, la Osteología está incorporando progresivamente el análisis estructural-biomecánico óseo y las interacciones músculo-esqueléticas. En este artículo se sintetizan los aportes originales del CEMFoC a la Osteología moderna en el terreno biomecánico en forma didáctica, para que el lector aprecie sus posibles aplicaciones clínicas. Los hallazgos aportaron evidencias sucesivas en apoyo de dos proposiciones fundamentales: a) los huesos deben interpretarse como estructuras resistivas, biológicamente servocontroladas (“Los huesos tienden siempre a mantener un factor de seguridad que permite al cuerpo trabajar normalmente sin fracturarse” – Paradigma de Utah) y b) los huesos interactúan con su entorno mecánico, determinado principalmente por las contracciones musculares, en forma subordinada al entorno metabólico (“Los huesos son lo que los músculos quieren que sean, siempre que las hormonas lo permitan”). Los avances producidos se refieren, tanto cronológica como didácticamente, al conocimiento osteológico en general y al desarrollo de recursos novedosos para el diagnóstico no invasivo de fragilidad ósea, para distinguir entre osteopenias y osteoporosis, y para discriminar entre sus etiologías ‘mecánica’ y ‘sistémica’. Finalmente, el nuevo conocimiento se integra en la proposición de un algoritmo diagnóstico para osteopenias y osteoporosis. El espíritu general de la presentación destaca que la evaluación osteomuscular dinámicamente integrada genera un nuevo espacio de análisis personalizado de los pacientes para la atención de cualquier osteopatía fragilizante con criterio biomecánico.
 
In consonance with the traditional spirit of our studies, skeletal research is being pro¬gressively focused on the structural-biomechanical analysis of bone and the muscle-bone interactions. In this article, the CEMFoC’s members summarize their original findings in bone biomechanics and their potential clinical applications. These findings provided evidence supporting two fundamental hypotheses, namely, A. bones constitute resistive struc¬tures, which are biologically servo-controlled (‘Bones tend to maintain a safety factor which allows the body to function normally avoiding fractures’ – the ‘Utah paradigm’), and B. the interactions of bones with their mechanical environment mainly are determined by the contraction of local muscles - ‘bone-muscle units’), and are subordinated to the control of the metabolic environment (‘Bones are what muscles wish them to be, provided that hormones allow for it’). The achievements in the field are presented in a chronological and didactical sequence concerning the general knowledge in Osteology and the development of novel resources for non-invasive diagnosis of bone fragility, aiming to distinguish between osteopenias and osteoporosis and the ‘mechanical’ and ‘metabolic’ etiology of these conditions. Finally, the integrated new knowledge is presented as supporting for a proposed diagnostic algorithm for osteopenias and osteoporosis. In general terms, the article highlights the dynamic evaluation of the musculoskeletal system as a whole, opening a new diagnostic field for a personalized evaluation of the patients affected by a bone-weakening disease, based on functional and biomechanical criteria
 
Palabras clave: BIOMECÁNICA ÓSEA , OSTEOPENIA , OSTEOPOROSIS , DENSITOMETRÍA ÓSEA , TOMOGRAFÍA ÓSEA , RELACIONES HUESO/MÚSCULO , SARCOPENIA , DINAMOMETRÍA
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 3.424Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Atribución-NoComercial-SinDerivadas 2.5 Argentina (CC BY-NC-ND 2.5 AR)
Identificadores
URI: http://hdl.handle.net/11336/104780
URL: http://www.osteologia.org.ar/files/pdf/rid58_125-147-ost2-4-ferretti-a.pdf
Colecciones
Articulos(CCT - ROSARIO)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - ROSARIO
Citación
Ferretti, Jose Luis; Cointry, Gustavo Roberto; Capozza, Ricardo Francisco; De la osteología a la osteomiología: tres décadas de aportes originales continuos al análisis biomecánico osteomuscular; Asociación Argentina de Osteología y Metabolismo Mineral; Actualizaciones en Osteología; 14; 2; 11-2018; 125-147
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES