Mostrar el registro sencillo del ítem
dc.contributor.author
Jalalvand, Ali R.
dc.contributor.author
Haseli, Ali
dc.contributor.author
Farzadfar, Farshad
dc.contributor.author
Goicoechea, Hector Casimiro
dc.date.available
2020-05-11T12:55:33Z
dc.date.issued
2019-04
dc.identifier.citation
Jalalvand, Ali R.; Haseli, Ali; Farzadfar, Farshad; Goicoechea, Hector Casimiro; Fabrication of a novel biosensor for biosensing of bisphenol A and detection of its damage to DNA; Elsevier Science; Talanta; 201; 4-2019; 350-357
dc.identifier.issn
0039-9140
dc.identifier.uri
http://hdl.handle.net/11336/104710
dc.description.abstract
In this work, a novel electrochemical biosensor has been fabricated based on step-by-step modification of aglassy carbon electrode (GCE) with methylene blue (MB)-DNA/multiwalled carbon nanotubes (MWCNTs)-chitosan (CS)/palladium nanoparticles (Pd NPs)/fullerene C60 (C60) for voltammetric and impedimetric detection of DNA damage induced by bisphenol A (BPA). Modifications applied to the GCE were characterized bycyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS)and scanning electron microscopy. The EIS and DPV responses of the biosensor were increased and decreased,respectively, by the DNA damage induced by BPA which led us to develop novel systems for detection of DNAdamage. Our records confirmed that the biosensor was able to rapid and sensitive detection of DNA damageinduced by BPA. Finally, according to the developed systems for detection of DNA damage, we have developedvoltammetric and impedimetric methods for determination of BPA
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Bisphenol A
dc.subject
DNA damage
dc.subject
Biosensor
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Fabrication of a novel biosensor for biosensing of bisphenol A and detection of its damage to DNA
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-05-04T20:59:00Z
dc.journal.volume
201
dc.journal.pagination
350-357
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Jalalvand, Ali R.. Kermanshah University Of Medical Sciences; Irán
dc.description.fil
Fil: Haseli, Ali. Kermanshah University Of Medical Sciences; Irán
dc.description.fil
Fil: Farzadfar, Farshad. Kermanshah University Of Medical Sciences; Irán
dc.description.fil
Fil: Goicoechea, Hector Casimiro. Universidad Nacional del Litoral; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.journal.title
Talanta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0039914019304266
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2019.04.037
Archivos asociados