Mostrar el registro sencillo del ítem

dc.contributor.author
Filippa, Leonardo Marcelo  
dc.contributor.author
Freire, Luana  
dc.contributor.author
Trento, Alfredo Emilio  
dc.contributor.author
Alvarez, Ana Maria Teresita  
dc.contributor.author
Gallo, Marcos Esteban  
dc.contributor.author
Vinzón, Susana  
dc.date.available
2020-04-23T14:54:12Z  
dc.date.issued
2011-07  
dc.identifier.citation
Filippa, Leonardo Marcelo; Freire, Luana; Trento, Alfredo Emilio; Alvarez, Ana Maria Teresita; Gallo, Marcos Esteban; et al.; Laboratory evaluation of two LISST-25X using river sediments; Elsevier Science; Sedimentary Geology; 238; 3-4; 7-2011; 268-276  
dc.identifier.issn
0037-0738  
dc.identifier.uri
http://hdl.handle.net/11336/103438  
dc.description.abstract
There are different methods to determine particle size, most of them are only applicable in the laboratory. In order to describe the suspended fine sediment sizes where flocs may be part of the suspension, in situ measurements are essential. Thiswork shows the results of sediment size measurements done in the laboratory using two LISST-25X diffractometers, developed for in-situ measurements, and a Malvern Mastersizer 2000 diffractometer for laboratory use. The two LISST-25X models characterize the sample size through the Sauter Mean Diameter (SMD). Besides the SMD, the Malvern diffractometer determines the granulometric distributions of the samples. The tested samples are from different fluvial and estuarine environments (Paran¨¢, Salado and the Amazon Rivers) and their sizes (SMD) range from 4 to 300 ¦Ìm. The relationship between SMD obtained with the two LISST-25X and the Malvern diffractometers gave a determination coefficient of R2=0.98. Compared to the Malvern instrument, used as a reference, it was observed that the LISST instruments tend to overestimate the measured SMD for diameters lower than 20 ¦Ìm, and to underestimate the values of samples with larger diameters (N20 ¦Ìm). Aiming to obtain other characteristic diameters of the granulometric distribution from SMD measurements obtained with LISST-25X diffractometers, correlations between SMD and d10, d50 and d90, were established. The dependency of the measurement of sediment mass concentration obtained with LISST instruments, with the particle size, is also addressed.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
LISST-25X  
dc.subject
SAUTER_MEAN_DIAMETER_(SMD)  
dc.subject
SEDIMENTS  
dc.subject
GRANULOMETRIC_DISTRIBUTION  
dc.subject.classification
Otras Ingeniería del Medio Ambiente  
dc.subject.classification
Ingeniería del Medio Ambiente  
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS  
dc.title
Laboratory evaluation of two LISST-25X using river sediments  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-04-21T15:20:28Z  
dc.journal.volume
238  
dc.journal.number
3-4  
dc.journal.pagination
268-276  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Filippa, Leonardo Marcelo. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina  
dc.description.fil
Fil: Freire, Luana. Universidade Federal do Rio de Janeiro; Brasil  
dc.description.fil
Fil: Trento, Alfredo Emilio. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina  
dc.description.fil
Fil: Alvarez, Ana Maria Teresita. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina  
dc.description.fil
Fil: Gallo, Marcos Esteban. Universidade Federal do Rio de Janeiro; Brasil  
dc.description.fil
Fil: Vinzón, Susana. Universidade Federal do Rio de Janeiro; Brasil  
dc.journal.title
Sedimentary Geology  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.sedgeo.2011.04.017