Mostrar el registro sencillo del ítem
dc.contributor.author
Filippa, Leonardo Marcelo
dc.contributor.author
Freire, Luana
dc.contributor.author
Trento, Alfredo Emilio
dc.contributor.author
Alvarez, Ana Maria Teresita
dc.contributor.author
Gallo, Marcos Esteban
dc.contributor.author
Vinzón, Susana
dc.date.available
2020-04-23T14:54:12Z
dc.date.issued
2011-07
dc.identifier.citation
Filippa, Leonardo Marcelo; Freire, Luana; Trento, Alfredo Emilio; Alvarez, Ana Maria Teresita; Gallo, Marcos Esteban; et al.; Laboratory evaluation of two LISST-25X using river sediments; Elsevier Science; Sedimentary Geology; 238; 3-4; 7-2011; 268-276
dc.identifier.issn
0037-0738
dc.identifier.uri
http://hdl.handle.net/11336/103438
dc.description.abstract
There are different methods to determine particle size, most of them are only applicable in the laboratory. In order to describe the suspended fine sediment sizes where flocs may be part of the suspension, in situ measurements are essential. Thiswork shows the results of sediment size measurements done in the laboratory using two LISST-25X diffractometers, developed for in-situ measurements, and a Malvern Mastersizer 2000 diffractometer for laboratory use. The two LISST-25X models characterize the sample size through the Sauter Mean Diameter (SMD). Besides the SMD, the Malvern diffractometer determines the granulometric distributions of the samples. The tested samples are from different fluvial and estuarine environments (Paran¨¢, Salado and the Amazon Rivers) and their sizes (SMD) range from 4 to 300 ¦Ìm. The relationship between SMD obtained with the two LISST-25X and the Malvern diffractometers gave a determination coefficient of R2=0.98. Compared to the Malvern instrument, used as a reference, it was observed that the LISST instruments tend to overestimate the measured SMD for diameters lower than 20 ¦Ìm, and to underestimate the values of samples with larger diameters (N20 ¦Ìm). Aiming to obtain other characteristic diameters of the granulometric distribution from SMD measurements obtained with LISST-25X diffractometers, correlations between SMD and d10, d50 and d90, were established. The dependency of the measurement of sediment mass concentration obtained with LISST instruments, with the particle size, is also addressed.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
LISST-25X
dc.subject
SAUTER_MEAN_DIAMETER_(SMD)
dc.subject
SEDIMENTS
dc.subject
GRANULOMETRIC_DISTRIBUTION
dc.subject.classification
Otras Ingeniería del Medio Ambiente
dc.subject.classification
Ingeniería del Medio Ambiente
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Laboratory evaluation of two LISST-25X using river sediments
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-04-21T15:20:28Z
dc.journal.volume
238
dc.journal.number
3-4
dc.journal.pagination
268-276
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Filippa, Leonardo Marcelo. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina
dc.description.fil
Fil: Freire, Luana. Universidade Federal do Rio de Janeiro; Brasil
dc.description.fil
Fil: Trento, Alfredo Emilio. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina
dc.description.fil
Fil: Alvarez, Ana Maria Teresita. Universidad Nacional del Litoral. Facultad de Ingeniería y Ciencias Hídricas; Argentina
dc.description.fil
Fil: Gallo, Marcos Esteban. Universidade Federal do Rio de Janeiro; Brasil
dc.description.fil
Fil: Vinzón, Susana. Universidade Federal do Rio de Janeiro; Brasil
dc.journal.title
Sedimentary Geology
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.sedgeo.2011.04.017
Archivos asociados