Wuilloud, Rodolfo German; Wuilloud, Gustavo M.; Altamirano, Jorgelina Cecilia; Olsina, Roberto Antonio; Martinez, Luis Dante; Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS; Perkin-Elmer Corporation; Atomic Spectroscopy; 23; 2; 3-2002; 44-51
dc.identifier.issn
0195-5373
dc.identifier.uri
http://hdl.handle.net/11336/103116
dc.description.abstract
A method for the pre-concentration and speciation of chromium was developed. On-line pre-concentration and determination were obtained using flame atomic absorption spectrometry (FAAS) coupled with flow injection (FI). To determine the total chromium present in water samples, the chromium species were retained on an Amberlite XAD-16 resin as chromium-4-(2-Thiazolylazo)-resorcinol (Cr-TAR) complex, at pH 5.0. On the other hand, Cr(VI) was determined by selective formation of Cr-TAR complexes with the use of 1,2 cyclohexane-diaminetetracetic acid (CDTA) as masking agent of Cr(III). The Cr-TAR complexes were formed by heating the reagents at 90?C for 50 minutes and then retained on the resin. The Cr-TAR complexes were removed from the micro-column with ethanol. The Cr(III) concentration was determined by the difference between the total chromium concentration and that of Cr(VI). A sensitivity enhancement factor of 250 was obtained with respect to the chromium determination in aqueous medium by FAAS (50 for pre-concentration and 5 due to the use of ethanol as solvent). The detection limit for the pre-concentration of 50 mL of aqueous solution was 20 ng/L. The precision for 10 replicate determinations at the 2.0-?g/L Cr level was 3.8% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and pre-concentration method for chromium species was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 ?g/L. The method was successfully applied to the speciation of chromium in water samples.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Perkin-Elmer Corporation
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
PRECONCENTRATION CHROMIUM
dc.subject
SPECIATION CHROMIUM
dc.subject
ATOMIC ABSORTION SPECTROMETRY (FAAS)
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Preconcentration and speciation of Cr(III) and Cr(VI) in water samples using amberlite XAD-16 resin and determination by flow injection-flame AAS
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-03-19T14:35:08Z
dc.journal.volume
23
dc.journal.number
2
dc.journal.pagination
44-51
dc.journal.pais
Estados Unidos
dc.journal.ciudad
Norwalk
dc.description.fil
Fil: Wuilloud, Rodolfo German. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina
dc.description.fil
Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina
dc.description.fil
Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina
dc.description.fil
Fil: Olsina, Roberto Antonio. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química Analítica; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.journal.title
Atomic Spectroscopy
Archivos asociados