Mostrar el registro sencillo del ítem
dc.contributor.author
Wuilloud, Gustavo M.
dc.contributor.author
Altamirano, Jorgelina Cecilia
dc.contributor.author
Wuilloud, Rodolfo German
dc.contributor.author
Silva, María Fernanda
dc.contributor.author
Olsina, Roberto Antonio
dc.contributor.author
Martinez, Luis Dante
dc.date.available
2020-03-27T20:54:53Z
dc.date.issued
2002-10-16
dc.identifier.citation
Wuilloud, Gustavo M.; Altamirano, Jorgelina Cecilia; Wuilloud, Rodolfo German; Silva, María Fernanda; Olsina, Roberto Antonio; et al.; Cloud point extraction of vanadium in parenteral solutions using a nonionic surfactant (PONPE 5.0) and determination by flow injection-inductively coupled plasma optical emission spectrometry; Elsevier Science; Talanta; 58; 4; 16-10-2002; 619-627
dc.identifier.issn
0039-9140
dc.identifier.uri
http://hdl.handle.net/11336/101179
dc.description.abstract
A preconcentration and determination methodology for vanadium at trace levels in parenteral solutions was developed. Cloud point extraction was successfully employed for the preconcentration of vanadium prior to inductively coupled plasma atomic optical emission spectrometry (ICP-OES) coupled to a flow injection (FI) system. The vanadium was extracted as vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol [V-(5-Br-PADAP)] complex, at pH 3.7 mediated by micelles of the nonionic surfactant polyoxyethylene (5.0) nonylphenol (PONPE 5.0). The extracted surfactant-rich phase (100 μl) was mixed with 100 μl of ethanol and this final volume injected into ICP-OES for the vanadium determination. Under these conditions, the 50 ml sample solution preconcentration allowed raising an enrichment factor of 250-fold; however, it was possible to obtain a theoretical enrichment factor of 500-fold. The lower limit of detection (LOD) obtained under the optimal conditions was 16 ng 1-1. The precision for 10 replicate determinations at the 2.0 μg-1 V level was 2.3% relative standard deviation (RSD), calculated with the peak heights. The calibration graph using the preconcentration system for vanadium was linear with a correlation coefficient of 0.9996 at levels near the detection limits up to at least 50 μg 1-1. The method was successfully applied to the determination of vanadium in parenteral solution samples.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
2-(5-BROMO-2-PYRIDYLAZO)-5-DIETHYLAMINOPHENOL REAGENT
dc.subject
CLOUD POINT EXTRACTION
dc.subject
ICP-OES
dc.subject
PARENTERAL SOLUTIONS
dc.subject
VANADIUM DETERMINATION
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Cloud point extraction of vanadium in parenteral solutions using a nonionic surfactant (PONPE 5.0) and determination by flow injection-inductively coupled plasma optical emission spectrometry
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2020-03-19T14:34:49Z
dc.journal.volume
58
dc.journal.number
4
dc.journal.pagination
619-627
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Wuilloud, Gustavo M.. Universidad Nacional de San Luis; Argentina
dc.description.fil
Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Wuilloud, Rodolfo German. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Silva, María Fernanda. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Olsina, Roberto Antonio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Martinez, Luis Dante. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina
dc.journal.title
Talanta
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0039914002003661
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/S0039-9140(02)00366-1
Archivos asociados