Mostrar el registro sencillo del ítem

dc.contributor.author
Ferreyra, Raquel Edith  
dc.contributor.author
Camiña, José Manuel  
dc.contributor.author
Marchevsky, Eduardo Jorge  
dc.contributor.author
Luco, Juan Maria  
dc.date.available
2020-03-19T18:59:21Z  
dc.date.issued
2000-12  
dc.identifier.citation
Ferreyra, Raquel Edith; Camiña, José Manuel; Marchevsky, Eduardo Jorge; Luco, Juan Maria; Simultaneous spectrophotometric determination of La, Ho, Mn 5-Br-PADAP complexes using multivariate calibration with partial least-squares (PLS) data evaluation; Springer Verlag Berlín; Fresenius Journal Of Analytical Chemistry; 368; 6; 12-2000; 595-600  
dc.identifier.issn
0937-0633  
dc.identifier.uri
http://hdl.handle.net/11336/100335  
dc.description.abstract
A simple and fast analytical pocedure is proposed for the simultaneous spectrophotometric determination of lanthanum, holmium and manganese in synthetic ceramics, (La(0.8-x) Hox Sr0.2 MnO3), by using the partial least-squares (PLS) method. As chromogenic agent 5-Br-PADAP [2-(5 -bromo-2-pyridylazo)-5 -diethylaminophenol] was used, which form colored complexes with the three elements studied. To avoid metal hydrolysis, a mixture of ethanol and Triton X-100 at pH 9.5 was used for all experiments. A set of 17 calibration solutions measured throughout the 400-700 nm wavelength range was used in the calibration step. The concentration range for Mn(II) was 1-12 × 10-6 mol L-1, while the range for the rare earth elements La(III) and Ho(III) was 2-8 × 10-6 mol L-1. In order to demonstrate the applicability of the proposed method, a set of artificial samples containing the three analytes in variable proportions was prepared and analyzed. The analytical results obtained were quite acceptable with relative errors not greater than 7% in most cases.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Springer Verlag Berlín  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
MULTIVARIATE  
dc.subject
CALIBRATION  
dc.subject
RARE EARTHS  
dc.subject
SPECTROPHOTOMETRIC  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Simultaneous spectrophotometric determination of La, Ho, Mn 5-Br-PADAP complexes using multivariate calibration with partial least-squares (PLS) data evaluation  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-03-19T14:33:42Z  
dc.journal.volume
368  
dc.journal.number
6  
dc.journal.pagination
595-600  
dc.journal.pais
Alemania  
dc.description.fil
Fil: Ferreyra, Raquel Edith. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Departamento de Química; Argentina  
dc.description.fil
Fil: Camiña, José Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Departamento de Química; Argentina  
dc.description.fil
Fil: Marchevsky, Eduardo Jorge. Consejo Nacional de Investigaciones Científicas y Técnicas; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Departamento de Química. Área de Química Analítica; Argentina  
dc.description.fil
Fil: Luco, Juan Maria. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Laboratorio de Alimentos; Argentina  
dc.journal.title
Fresenius Journal Of Analytical Chemistry  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007/s002160000549  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s002160000549