dc.description.abstract
In this work, Amberlite XAD-1180 resin is used for on-line surfactant-mediated pre-concentration of sildenafil as a prior step for its fluorescent detection. In order to activate the column for sildenafil pre-concentration, the cationic surfactant (hexadecyltrimethylammoniunm bromide, HTAB) is adsorbed onto the resin. In these conditions, sildenafil is retained by HTAB–resin and then it is eluted with ethanol and analyzed by spectrofluorimetry. Drug–surfactant association produces a considerable fluorescence enhancement, increasing considerably the sensitivity of detection. Therefore, sildenafil can be pre-concentrated and quantitatively determined, with a detection limit of 0.2 ng mL1 . The proposed method was successfully applied to the analysis of bulk drug, human urine, tablets, and local herbal medicine. Validation processes were performed by recovering studies and statistical analysis with satisfactory results.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
On-Line Preconcentration  
dc.subject
Fia-Fluorescence  
dc.subject
Polymeric Resin  
dc.subject
Surfactant  
dc.subject
Sildenafil  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Automated flow system for sildenafil enrichment using surfactant coated solid-phase with fluorescence detection  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2016-11-24T19:23:22Z  
dc.journal.volume
98  
dc.journal.pagination
247-252  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Wang, Chien Chun. Universidad Nacional de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Sombra, Lorena Luján. Universidad Nacional de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Fernandez, Liliana Patricia. Universidad Nacional de San Luis; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico San Luis. Instituto de Química de San Luis; Argentina  
dc.journal.title
Talanta  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.talanta.2012.07.003  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0039914012005516