Mostrar el registro sencillo del ítem
dc.contributor.author
Peralta, Cecilia Mariana
dc.contributor.author
Fernandez, Liliana Patricia
dc.contributor.author
Masi, Adriana Noemi
dc.date.available
2019-12-23T19:43:23Z
dc.date.issued
2011-05-06
dc.identifier.citation
Peralta, Cecilia Mariana; Fernandez, Liliana Patricia; Masi, Adriana Noemi; Solid phase extraction using nylon membranes with fluorescence detection as a fast and sensitive method for Amiloride and Furosemide determination in urine samples; Elsevier Science; Microchemical Journal; 98; 1; 6-5-2011; 39-43
dc.identifier.issn
0026-265X
dc.identifier.uri
http://hdl.handle.net/11336/92845
dc.description.abstract
A diuretic is a substance widely prohibited in competition sports, by the World Anti-Doping Agency (WADA). In this paper, a sensitive, rapid and convenient analytical solid phase extraction-fluorimetric method for the determination of furosemide (FUR) and amiloride hydrochloride (AMI) diuretics in human urine was developed. FUR and AMI exhibit overlapped fluorescent spectra and urine produces background fluorescence that precludes the direct determination of these diuretics by conventional fluorimetry. AMI was adsorbed using nylon membranes whereas; FUR was detected in aqueous solutions. The optimum analytical conditions for AMI and FUR assay were established. Excitation wavelengths of 365nm and 237nm and emission wavelengths of 406 and 415nm were used for AMI and FUR, respectively. The calibration graphs are linear in the range of 3.7×10-4 to 0.8 μgmL-1 and 1.2×10-3 to 4.0 μgmL-1, for AMI and FUR, respectively, with a detection limit of 1.1×10-4 and 3.5×10-4μgmL-1 (S/N=3). These concentrations correspond well with the range of the drugs in urine. AMI and FUR were accurately quantified in doped urine samples and urine of subjects under medical treatment with diuretic. The results were validated by recovery test, being highly satisfactory.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
AMILORIDE
dc.subject
FLUORESCENCE
dc.subject
FUROSEMIDE
dc.subject
NYLON MEMBRANE
dc.subject
SOLID PHASE EXTRACTION
dc.subject
URINE
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Solid phase extraction using nylon membranes with fluorescence detection as a fast and sensitive method for Amiloride and Furosemide determination in urine samples
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2019-08-26T18:35:55Z
dc.identifier.eissn
0026-265X
dc.journal.volume
98
dc.journal.number
1
dc.journal.pagination
39-43
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Peralta, Cecilia Mariana. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Química de San Luis; Argentina
dc.description.fil
Fil: Masi, Adriana. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Química de San Luis; Argentina
dc.journal.title
Microchemical Journal
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.microc.2010.10.009
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0026265X10002158
Archivos asociados