dc.description.abstract
This work introduces a new, versatile and robust X-ray detector with hemispherical 2π geometry, based on a set of 15 small cylindrical proportional counters located in a hexagonal and pentagonal fullerene C60 pattern, at the same distance from the center (where a sample is placed). The counteranode consists of stainless steel sewing needles with spherical tips measuring approximately 80μm in diameter. The space between the counters and the sample could contain air, the same gas as the counters or vacuum. This allows a significant increase in the count rates by a factor approximately equal to the number of counters connected. It is shown that an energy resolution of 20% for 5.9keV photons can be obtained, and a global counting rate of around 106counts/s is achievable by the 15 Needle Anode Proportional Counters (NAPCs) operating in parallel mode, in our setup.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Pergamon-Elsevier Science Ltd  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
Gas Proportional Counter  
dc.subject
Needles Anode  
dc.subject
X-Ray Detectors  
dc.subject.classification
Astronomía  
dc.subject.classification
Ciencias Físicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Characterization of hemispherical area X-ray detector based on set of proportional counters with needle anodes  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2019-03-13T17:37:51Z  
dc.journal.volume
107  
dc.journal.pagination
191-194  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Figueroa, Rodolfo G.. Universidad de La Frontera; Chile  
dc.description.fil
Fil: Santibañez, Mauricio. Universidad de La Frontera; Chile  
dc.description.fil
Fil: Valdes, Cristian. Centro Oncológico de Antofagasta; Chile  
dc.description.fil
Fil: Valente, Mauro Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina  
dc.journal.title
Applied Radiation and Isotopes  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/http://www.sciencedirect.com/science/article/pii/S0969804315302190  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.apradiso.2015.10.027