Preliminary study on the biocompatibility and osteoconductive properties of a new bovine bone graft

Título: Estudio preliminar sobre las propiedades de biocompatibilidad y osteoconductividad de un nuevo injerto de hueso bovino
Pellegrini, Gretel GiselaIcon ; Gonzales Chaves, Macarena Maria SolIcon ; Orzuza, Ricardo; Zeni, Susana NoemiIcon
Fecha de publicación: 05/2017
Editorial: Asociación Argentina de Osteología y Metabolismo Mineral
Revista: Actualizaciones en Osteología
ISSN: 1669-8975
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Salud Ocupacional

Resumen

 
Para prevenir la resorción post-exodoncia y preservar la integridad de los rebordes alveolares, se recomienda la colocación de injertos óseos en el momento de la extracción. Los injertos de hueso bovino son biocompatibles y osteoconductivos, permitiendo nueva aposición ósea por células osteoprogenitoras. Existen marcas internacionales de injertos de hueso bovino, pero resultan caros e incluso difíciles de adquirir. Por ello, la elaboración de biomateriales de alta calidad, nacionales, reduciría los altos costos de salud pública en odontología. En este estudio, se evaluaron y compararon los efectos de un injerto de hueso bovino fabricado en Argentina (Synergy Bone Matrix) versus un injerto de hueso bovino reconocido por sus efectos osteoconductivos (Bio-Oss), en el proceso de cicatrización ósea en un modelo experimental en ratas. Para ello, creamos un defecto óseo crítico en tibia de rata los cuales se rellenaron con uno de los injertos de hueso bovino o control. Se evaluó: respuesta clínica y radiográfica, densidad mineral ósea e histología. No se observaron abscesos, encapsulación, supuración o inflamación de los ganglios linfáticos. Radiográficamente, todos los implantes se integraron a los márgenes óseos circundantes, sugiriendo una cicatrización adecuada. Por el contrario, las tibias control no mostraron signos de recuperación con formación de tejido fibroso. No se observaron diferencias estadísticas en las BMC y BMD entre las tibias Synergy Bone Matrix o Bio-Oss. La histología reveló partículas de ambos injertos óseos rodeadas por tejido óseo laminar indicando osteoconductividad sin signos inflamatorios. Este estudio preliminar sugiere que Synergy Bone Matrix presenta propiedades similares de biocompatibilidad y osteoconductividad que Bio-Oss.
 
To prevent post-extraction resorption and preserve the integrity of the alveolar ridges, the placement of bone grafts at the time of extraction is recommended. Bovine bone grafts are biocompatibile and osteoconductive, allowing new bone apposition by osteoprogenitor cells. Although there are trademarks recognized internationally regarding bovine bone grafts, they are expensive and even difficult to acquire. Therefore, domestic industry development of high quality biomaterials will reduce the public health high costs in the dental field. Here, we evaluated and compared the effects of an Argentinean manufactured bovine bone graft (Synergy Bone Matrix) with a bovine bone graft recognized for its osteoconductive effects (Bio-Oss), on bone healing in an experimental model in rats. We created critical sized bone defects in rat tibiae and filled them with either one of the bovine bone grafts or control. Clinical responses, X-ray findings, bone mineral density, and histological parameters were evaluated. No abscess, encapsulation, suppuration or inflammation of lymphatic nodes were observed. Radiographically, all implants were amalgamated to the surrounding bony margins, suggesting proper healing. On the other hand, control tibiae exhibited no signs of recovery and remained either unfilled or showed fibrous tissue formation. No statistical differences were observed in BMC and BMD between tibiae filled with Synergy Bone Matrix or Bio-Oss. Histological analysis revealed particles of both bone grafts surrounded by laminar bone tissue indicating osteoconductivity, without any inflammatory sign. This preliminary study suggests that Synergy Bone Matrix, as well as Bio-Oss, present similar properties of biocompatibility and osteoconductivity
 
Palabras clave: Biocompatibilidad , Osteoconduccion , Material de Relleno , Ratas
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 623.8Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/66301
URL: http://osteologia.org.ar/?s=ver_articulo&id=3000&t=Estudio%20preliminar%20sobre%
Colecciones
Articulos(INIGEM)
Articulos de INSTITUTO DE INMUNOLOGIA, GENETICA Y METABOLISMO
Citación
Pellegrini, Gretel Gisela; Gonzales Chaves, Macarena Maria Sol; Orzuza, Ricardo; Zeni, Susana Noemi; Preliminary study on the biocompatibility and osteoconductive properties of a new bovine bone graft; Asociación Argentina de Osteología y Metabolismo Mineral; Actualizaciones en Osteología; 13; 2; 5-2017; 116-124
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES