A new algorithm for estimating the rod volume fraction and the trabecular thickness from in vivo computed tomography

Thomsen, Felix Sebastian LeoIcon ; Peña, Jaime Andrés; Lu, Yongtao; Huber, Gerd; Morlock, Michael; Glüer, Claus Christian; Delrieux, Claudio AugustoIcon
Fecha de publicación: 12/2016
Editorial: American Association of Physicists in Medicine
Revista: Medical Physics
ISSN: 0094-2405
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Ingeniería de Sistemas y Comunicaciones; Ingeniería Médica

Resumen

Purpose: Existing microstructure parameters are able to predict vertebral in vitro failure load, but for noisy in vivo data more complex algorithms are needed for a robust assessment. Methods: A new algorithm is proposed for the microstructural analysis of trabecular bone under in vivo quantitative computed tomography (QCT). Five fractal parameters are computed: (1) the average local fractal dimension FD, (2) its standard deviation FD.SD, (3) the fractal rod volume ratio fRV/BV, (4) the average fractal trabecular thickness fTb.Th, and (5) its coefcient of variation fTb.Th.CV. The algorithm requires neither an explicit skeletonization of the trabecular bone, nor a well-defned transition between bone and marrow phases. Two experiments were conducted to compare the fractal with established microstructural parameters. In the frst, 20 volumes-of-interest of embedded vertebrae phantoms were scanned fve times under QCT and high-resolution (HR-)QCT and once under peripheral HRQCT (HRpQCT), to derive accuracy and precision. In the second experiment, correlations between in vitro HRQCT structural parameters were obtained from 76 human T11, T12, or L1 vertebrae. In vitro fracture data were available for a subset of 17 human T12 vertebrae so that linear regression models between failure load and microstructural HRQCT parameters could be analyzed. Results: The results showed correlations of fTb.Th and fRV/BV with their nonfractal pendants trabecular thickness (Tb.Th) and respective structure model index (SMI) while higher precision and accuracy was observed on the fractal measures. Linear models of bone mineral density with two and three fractal microstructural HRQCT parameters explained 86% and 90% (adjusted R2) of the failure load and signifcantly improved the linear models based only on BMD and established standard microstructural parameters (68%-77% adjusted R2). Conclusions: The application of fractal methods may grant further insight into the study of bone quality in vivo when image resolution and quality are less than optimal for current standard methods.
Palabras clave: Failure Load , Local Fractal Dimension , Qct , Rod Volume Ratio , Trabecular Thickness
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.319Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/59366
URL: https://aapm.onlinelibrary.wiley.com/doi/abs/10.1118/1.4967479
DOI: http://dx.doi.org/10.1118/1.4967479
Colecciones
Articulos(CCT - BAHIA BLANCA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - BAHIA BLANCA
Citación
Thomsen, Felix Sebastian Leo; Peña, Jaime Andrés; Lu, Yongtao; Huber, Gerd; Morlock, Michael; et al.; A new algorithm for estimating the rod volume fraction and the trabecular thickness from in vivo computed tomography; American Association of Physicists in Medicine; Medical Physics; 43; 12; 12-2016; 6598-6607
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES