Mostrar el registro sencillo del ítem
dc.contributor.author
Villalba, Ayelén María
dc.contributor.author
Correa Cantaloube, Erica Norma
dc.contributor.author
Pattini, Andrea Elvira
dc.contributor.author
Vicare Lisanti, Daniel Eduardo
dc.date.available
2018-04-03T16:17:21Z
dc.date.issued
2017-07
dc.identifier.citation
Villalba, Ayelén María; Correa Cantaloube, Erica Norma; Pattini, Andrea Elvira; Vicare Lisanti, Daniel Eduardo; Hot-cool box calorimetric determination of the solar heat gain coefficient and the U-value of internal shading devices; Springer Netherlands; Energy Efficiency; 10; 6; 7-2017; 1553-1571
dc.identifier.issn
1570-646X
dc.identifier.uri
http://hdl.handle.net/11336/40493
dc.description.abstract
In several developing countries, energy performance rating programs are currently in progress. Complex fenestration systems (CFS) are building components that play a key role in reducing energy consumption. The development and testing of equipment is central for beginning the energy efficiency rating process of complex glazing systems in these countries. This paper validates the use of a low-cost hot-cold box calorimeter for measurement of the solar heat gain coefficient (SGHC) and overall heat transfer coefficient (U-value) of interior shading systems. This work aims to determine the energy performance of three types of often employed shading systems: solar control films, interior horizontal venetian blinds, and indoor drapery curtains. Results show that the energy performance of solar shading devices studied depends on both their morphological and optical properties. The shading systems analyzed present similar U-values, where technological features are represented by the thickness and the thermal conductivity of the material. SHGC is mainly defined by the transmittance and, to a lesser extent, the absorptance of the systems, which differ significantly according to the analyzed shading device. The three types of curtains analyzed demonstrate an SHGC dependent on the fabrics openness factor: jacquard curtains (openness factor 0.05) present a SHGC of 0.7, whereas organza curtains (openness factor 0.45) have a SHGC of 0.82. The SHGC of the venetian blinds analyzed varies on average 36% according to the slat tilt (0°?45°). The solar control films examined modify their solar gain according to their spectral selectivity.
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Springer Netherlands
dc.rights
info:eu-repo/semantics/openAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
Hot-Cool Box Calorimeter
dc.subject
Solar Control Systems
dc.subject
Solar Heat Gain Coefficient
dc.subject
U-Value
dc.subject.classification
Ingeniería Medioambiental y Geológica, Geotécnicas
dc.subject.classification
Ingeniería del Medio Ambiente
dc.subject.classification
INGENIERÍAS Y TECNOLOGÍAS
dc.title
Hot-cool box calorimetric determination of the solar heat gain coefficient and the U-value of internal shading devices
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2018-03-27T13:39:04Z
dc.identifier.eissn
1570-6478
dc.journal.volume
10
dc.journal.number
6
dc.journal.pagination
1553-1571
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Villalba, Ayelén María. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ambiente, Hábitat y Energía; Argentina
dc.description.fil
Fil: Correa Cantaloube, Erica Norma. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ambiente, Hábitat y Energía; Argentina
dc.description.fil
Fil: Pattini, Andrea Elvira. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto de Ambiente, Hábitat y Energía; Argentina
dc.description.fil
Fil: Vicare Lisanti, Daniel Eduardo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza; Argentina
dc.journal.title
Energy Efficiency
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1007/s12053-017-9544-1
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://link.springer.com/article/10.1007/s12053-017-9544-1
Archivos asociados