Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Identificación de series de suelos mediante el uso de sensores de conductividad eléctrica aparente en el sudeste bonaerense

Título: Identification of soil series with apparent electrical conductivity sensors in the southeastern pampas
Paggi, Mariano; Peralta, Nahuel RaúlIcon ; Calandroni, Mirta Beatriz; Cabria, Fabián Néstor; Costa, Jose Luis; Aparicio, Virginia CarolinaIcon
Fecha de publicación: 05/2013
Editorial: Asociación Argentina de la Ciencia del Suelo
Revista: Ciencia del Suelo
ISSN: 0326-3169
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Ciencias del Suelo

Resumen

 
Durante el siglo pasado, se elaboraron mapas de suelo en la provincia de Buenos Aires a una escala de 1:50000. Por lo general, los lotes de producción del Sudeste Bonaerense contienen más de una unidad cartográfica con distintas series de suelo con diferentes aptitudes agrícolas. En los mapas a escala 1:50000, la ubicación precisa de estas series de suelo no siempre se logra identificar. La profundidad efectiva del perfil del suelo es un indicador de las series de suelo. El objetivo del presente trabajo fue: (l) examinar la estructura espacial de la CEa  (ll) evaluar la relación espacial de la Conductividad Eléctrica Aparente del suelo entre diferentes sensores (Geonics EM38-mk2 y veris 3100); y (lll)  evaluar la relación espacial de la CEa y la profundidad del suelo, como un indicador de la serie de suelo. Los muestreos se efectuaron en un lote de 16 ha, ubicado en la EEA Balcarce. La medición de la CEa  fue realizada con un sensor de no-contacto (Geonics EM38-mk2) en la orientación dipolo vertical (0?150 cm de profundidad) midiendo la CEa por inducción electromagnética, y un sensor de contacto (Veris 3100) (0-30 y 0?90 cm de profundidad). La profundidad del suelo fue medida a una distancia promedio de 25 m con un muestreador hidráulico (Guiddding). Los datos colectados  con el EM38-mk2 en la orientación dipolo vertical (0?150 cm de profundidad) y Veris 3100 (0?90 cm de profundidad) presentaron las mayores correlaciones espaciales (r=.0, 77) La profundidad del suelo estuvo principalmente asociada a la CEa superficial (0-30 cm) medida por el Veris 3100 (r=.-0,58). La CEa puede usarse como indicador de la serie de suelo en lotes que presenten variabilidad en su profundidad efectiva.
 
During the last century, soil maps were developed in the province of Buenos Aires on a scale of 1:50000. Generally, fields in t Southeastern pampas contain more than one mapping unit composed of different soil series with several agricultural aptitudes. In the 1:50000 scale maps, the precise location of these soil series are not always successfully identified. The effective depth of the soil profile is an indicator of soil series. The objectives of this study were to: (l) examine the spatial structure of apparent electrical conductivity (ECa ), (ll) evaluate the spatial relationship of soil ECa between different sensors (Geoids EM38-mk2 y veris 3100); and (lll) to evaluate the spatial relationship of ECa and soil depth, as an indicator of soil series. Sampling was carried out in a field of 16 ha, located in the EEA Balcarce. The measurement of ECa was performed using a non-contact sensor (Geonics EM38-MK2) in a vertical dipole orientation (0-150 cm depth) and a contact sensor (Veris 3100) (0-30 and 0-90 cm depth). Soil depth was measured at an average distance between sampling points of 25 m with a Giddings hydraulic sampler. The highest spatial correlations (r= -0.77) were achieved with data collected with the EM38-mk2 (0-150 cm depth) and Veris 3100 (0-90 cm depth)). Soil depth was mainly associated with surface ECa (0- 30 cm) measured by Veris 3100 (r= -0.58). Therefore, ECa can be used as an indicator of the soil series in fields with depth variability
 
Palabras clave: Cartografía Digital , Profundidad de Suelo , Variabilidad Espacial , Conductividad Eléctrica Aparente
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 3.162Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/3322
URL: http://www.scielo.org.ar/scielo.php?script=sci_arttext&pid=S1850-206720130002000
Colecciones
Articulos(CCT - MAR DEL PLATA)
Articulos de CTRO.CIENTIFICO TECNOL.CONICET - MAR DEL PLATA
Citación
Paggi, Mariano; Peralta, Nahuel Raúl; Calandroni, Mirta Beatriz; Cabria, Fabián Néstor; Costa, Jose Luis; et al.; Identificación de series de suelos mediante el uso de sensores de conductividad eléctrica aparente en el sudeste bonaerense; Asociación Argentina de la Ciencia del Suelo; Ciencia del Suelo; 31; 2; 5-2013; 175-188
Compartir

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES