The sensitivity and specificity of pulmonary carbon dioxide elimination for noninvasive assessment of fluid responsiveness

Tusman, Gerardo; Groisman, Ivan; Maidana, Gustavo A.; Scandurra, Adriana G.; Martinez Arca, JorgeIcon ; Bohm, Stephan H.; Suarez-Sipmann, Fernando
Fecha de publicación: 01/05/2016
Editorial: Lippincott Williams
Revista: Anesthesia And Analgesia
ISSN: 0003-2999
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Medicina Critica y de Emergencia

Resumen

BACKGROUND: We sought to determine whether the response of pulmonary elimination of CO2 (Vco2) to a sudden increase in positive end-expiratory pressure (PEEP) could predict fluid responsiveness and serve as a noninvasive surrogate for cardiac index (CI).METHODS: Fifty-two patients undergoing cardiovascular surgery were included in this study. By using a constant-flow ventilation mode, we performed a PEEP challenge of 1-minute increase in PEEP from 5 to 10 cm H2O. At PEEP of 5 cm H2O, patients were preloaded with 500 mL IV salinesolution after which a second PEEP challenge was performed. Patients in whom fluid administration increased CI by ≥15% from the individual baseline value were defined as volume responders.Beat-by-beat CI was derived from arterial pulse contour analysis, and breath-by-breath Vco2 data were collected during the protocol. The sensitivity and specificity of Vco2 for detecting thefluid responders according to CI was performed by the receiver operating Characteristic curves.RESULTS: Twenty-one of 52 patients were identified as fluid responders (40%). The PEEP maneuver before fluid administration decreased CI from 2.65 ± 0.34 to 2.21 ± 0.32 L/min/m2 (P = 0.0011) and Vco2 from 150 ± 23 to 123 ± 23 mL/min (P = 0.0036) in responders, whereas the changes in CI and Vco2 were not significant in nonresponders. The PEEP challenge afterfluid administration induced no significant changes in CI and Vco2, in neither responders nor nonresponders. PEEP-induced decreases in CI and Vco2 before fluid administration were well correlated (r2 = 0.75, P < 0.0001) but not thereafter. The area under the receiver operating characteristic curves for a PEEP-induced decrease in ΔCI and ΔVco2 was 0.99, with a 95% confidence interval from 0.96 to 0.99 for ΔCI and from 0.97 to 0.99 for ΔVco2. During the PEEP challenge,a decrease in Vco2 by 11% predicted fluid responsiveness with a sensitivity of 0.90 (95% confidence interval, 0.87?0.93) and a specificity of 0.95 (95% confidence interval, 0.92?0.98).CONCLUSIONS: PEEP-induced changes in Vco2 predicted fluid responsiveness with accuracy in patients undergoing cardiac surgery. (Anesth Analg 2016;122:1404?11)
Palabras clave: Sensitivity And Specificity , Carbon Dioxide Elimination , Fluid Responsiveness , Cardiac Index
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 660.8Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/33214
URL: https://insights.ovid.com/pubmed?pmid=26505574
DOI: http://dx.doi.org/10.1213/ANE.0000000000001047
Colecciones
Articulos(INTEMA)
Articulos de INST.DE INV.EN CIENCIA Y TECNOL.MATERIALES (I)
Citación
Tusman, Gerardo; Scandurra, Adriana G.; Maidana, Gustavo A.; Martinez Arca, Jorge; Suarez-Sipmann, Fernando; Groisman, Ivan; et al.; The sensitivity and specificity of pulmonary carbon dioxide elimination for noninvasive assessment of fluid responsiveness; Lippincott Williams; Anesthesia And Analgesia; 122; 5; 1-5-2016; 1404-1411
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES