Mostrar el registro sencillo del ítem

dc.contributor.author
Lanaro, Verónica Mariél  
dc.contributor.author
Sombra, Lorena Luján  
dc.contributor.author
Altamirano, Jorgelina Cecilia  
dc.contributor.author
Almeida, César Américo  
dc.contributor.author
Stege, Patricia Wanda  
dc.date.available
2025-03-26T15:34:08Z  
dc.date.issued
2024-02  
dc.identifier.citation
Lanaro, Verónica Mariél; Sombra, Lorena Luján; Altamirano, Jorgelina Cecilia; Almeida, César Américo; Stege, Patricia Wanda; Chiral separation of propranolol by electrokinetic chromatography using nanodiamonds and human serum albumin as a pseudo-stationary phase in river water; Wiley-liss, div John Wiley & Sons Inc.; Chirality; 36; 2; 2-2024; 1-10  
dc.identifier.issn
0899-0042  
dc.identifier.uri
http://hdl.handle.net/11336/257260  
dc.description.abstract
Propranolol is currently considered as an emerging contaminant in water bodies. In this study, R- and S-propranolol were determined in river samples by electrokinetic chromatography (EKC) using nanodiamonds (NDs) and human serum albumin (HSA) as a pseudo-stationary phase in order to achieve enantioseparation. Previously, river samples were preconcentrated using a column filled with Amberlite® IR-120 and Dowex® 50WX8 resins. The setting up of influential factors such as temperature, voltage, pH, and HSA and NDs concentration is accurately described along this manuscript. A multivariate study and optimization was carried out to obtain the enantioseparation of propranolol (Rs = 2.91), which was reached under the following experimental conditions: voltage of 16 kV, temperature of 16°C, phosphate buffer pH 9.5, NDs of 0.20%, and HSA of 15 μmol l−1. The recoveries of analytes under optimal conditions were higher than 98%. The limits of detection were 0.85 μg l−1 for R- and S-propranolol. The method was applied to real samples, and the obtained results in three different water sources studied were 1.02, 0.59, and 0.30 μg l−1 for the R-enantiomer and 0.99, 0.54, and 0.28 μg l−1 for the S-enantiomer. The accuracy of the proposed methodology (including bias and precision) has allowed us to propose it as a successful tool for the control of water quality.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Wiley-liss, div John Wiley & Sons Inc.  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
ELECTROKINETIC CHROMATOGRAPHY  
dc.subject
ENANTIOSEPARATION  
dc.subject
HUMAN SERUM ALBUMIN  
dc.subject
NANODIAMONDS  
dc.subject
PROPRANOLOL  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Chiral separation of propranolol by electrokinetic chromatography using nanodiamonds and human serum albumin as a pseudo-stationary phase in river water  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2025-03-25T20:56:06Z  
dc.journal.volume
36  
dc.journal.number
2  
dc.journal.pagination
1-10  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Lanaro, Verónica Mariél. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis; Argentina  
dc.description.fil
Fil: Sombra, Lorena Luján. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis; Argentina. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina  
dc.description.fil
Fil: Altamirano, Jorgelina Cecilia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales. Provincia de Mendoza. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales. Universidad Nacional de Cuyo. Instituto Argentino de Nivología, Glaciología y Ciencias Ambientales; Argentina  
dc.description.fil
Fil: Almeida, César Américo. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis; Argentina  
dc.description.fil
Fil: Stege, Patricia Wanda. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto Multidisciplinario de Investigaciones Biológicas de San Luis. Universidad Nacional de San Luis. Facultad de Ciencias Físico Matemáticas y Naturales. Instituto Multidisciplinario de Investigaciones Biológicas de San Luis; Argentina  
dc.journal.title
Chirality  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/full/10.1002/chir.23640  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1002/chir.23640