Mostrar el registro sencillo del ítem
dc.contributor.author
Acquaviva, Agustín
dc.contributor.author
Castells, Cecilia Beatriz Marta
dc.date.available
2025-03-06T17:48:28Z
dc.date.issued
2024-10
dc.identifier.citation
Acquaviva, Agustín; Castells, Cecilia Beatriz Marta; Modulation optimization when using a splitter pump after the first dimension in comprehensive two- dimensional liquid chromatography; Elsevier Science; Journal of Chromatography - A; 1734; 10-2024; 465319, 1-17
dc.identifier.issn
0021-9673
dc.identifier.uri
http://hdl.handle.net/11336/255603
dc.description.abstract
The rapid growth in the use of two dimensional liquid chromatography (2D-LC) applied to the analysis of moderately to highly complex mixtures, has been fueled by continuous improvements in performance and robustness of the instrument components, as well as the ease-of-use of software necessary for controlling the 2D-LC instrument hardware, and analysis of the large data files that result from this type of work.This work has focused on the evaluation of the performance of an online full comprehensive mode (LC×LC), when an active modulation is implemented using a flow splitter pump placed after the 1D effluent. Two different types of splitting pumps were evaluated: a binary ultra-high pressure liquid chromatography (UHPLC) pump and a high precision syringe pump. We analyzed the performance (reproducibility in peak area and retention times and the 2D peak dispersion) as a function of the location of the active pump Before or After the modulation valve, and the influence of connecting tubes (based on internal diameter and length) necessary between the interface, waste, and the splitting pump. The effect on the flow direction on the filling and flushing of the injection loops at the modulation valve was also analyzed for each pump.In this study, we demonstrate that flow-splitting LCxLC assembly can be performed using either a UHPLC binary pump or a simple syringe pump. Flow splitting after the first dimension is a straightforward strategy to: (i) independently select the 1D column and flow rates with respect to the second dimension; (ii) consciously dilute the eluate according to the solvent characteristics of the second dimension, thereby avoiding 2D peak distortions; and (iii) adapt the injected amount to the second column according to the relative concentration of the components in a complex sample. However, careful consideration of the system setup is necessary. It is demonstrated how experimental results can be significantly affected in terms of peak broadening and reproducibility if optimization of the interface is not taken into account.In addition, under the optimized conditions, the reproducibility in peak area and dispersion in the 2D dimension were evaluated as a function of the amount of sample transferred in terms of percentage of filled loop
dc.format
application/pdf
dc.language.iso
eng
dc.publisher
Elsevier Science
dc.rights
info:eu-repo/semantics/restrictedAccess
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.subject
ONLINE FULL COMPREHENSIVE 2D-LC
dc.subject
ACTIVE SPLITTER PUMP
dc.subject
REPRODUCIBILITY
dc.subject
2D PEAK DISPERSION
dc.subject
2D PEAK AREA
dc.subject
LOOP FILLING
dc.subject.classification
Química Analítica
dc.subject.classification
Ciencias Químicas
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS
dc.title
Modulation optimization when using a splitter pump after the first dimension in comprehensive two- dimensional liquid chromatography
dc.type
info:eu-repo/semantics/article
dc.type
info:ar-repo/semantics/artículo
dc.type
info:eu-repo/semantics/publishedVersion
dc.date.updated
2025-03-05T15:50:55Z
dc.journal.volume
1734
dc.journal.pagination
465319, 1-17
dc.journal.pais
Países Bajos
dc.journal.ciudad
Amsterdam
dc.description.fil
Fil: Acquaviva, Agustín. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina
dc.description.fil
Fil: Castells, Cecilia Beatriz Marta. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina
dc.journal.title
Journal of Chromatography - A
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://linkinghub.elsevier.com/retrieve/pii/S0021967324006939
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.chroma.2024.465319
Archivos asociados