Mostrar el registro sencillo del ítem

dc.contributor.author
Cora Jofré, Florencia  
dc.contributor.author
Azcarate, Silvana Mariela  
dc.contributor.author
Camiña, José Manuel  
dc.contributor.author
Pacheco, Pablo Hugo  
dc.contributor.author
Savio, Marianela  
dc.date.available
2024-04-09T12:38:39Z  
dc.date.issued
2023-02  
dc.identifier.citation
Cora Jofré, Florencia; Azcarate, Silvana Mariela; Camiña, José Manuel; Pacheco, Pablo Hugo; Savio, Marianela; Assessing the greenness of optimized ultrasound and infrared assisted extraction through analytical metrics; Elsevier; Advances in Sample Preparation; 5; 2-2023; 1-34  
dc.identifier.issn
2772-5820  
dc.identifier.uri
http://hdl.handle.net/11336/232497  
dc.description.abstract
Sample preparation involves a critical step due to the high organic matter content that implies its decomposition, prior to analysis. Two alternative analytical strategies for sample preparation employing diluted HNO3 were optimized and compared, assisted by ultrasound (USAE) and infrared (IRAE) radiation. Multielement determination was achieved by MIP OES. For optimization of experimental conditions, a central composite design centered on the faces was carried out, considering four and five factors for IRAE and USAE, respectively. Dissolved organic carbon (DOC), residual acidity (RA) and solid residue (SR), significantly influence the responses to be evaluated. The response surface methodology was implemented to find the best combination of mass, diluted reagents (HNO3 and H2O2), time and temperature in order to minimize responses for elemental extraction in animal feed samples. The optimized experimental conditions: 500 mg of sample mass, 60°C of bath temperature, 30 min of extraction time, 2 mol L−1 HNO3 and 27% H2O2, were used to validate the USAE procedure. The conditions established for IRAE were 500 mg of the swine feed sample, followed by the addition of 2 mL of 2 mol L−1 HNO3 and 23% H2O2, irradiating for 23 min. Recoveries ranged from 81 to 114%, with good precision (RSD < 4%). Using five index tools the greenness of the proposed methods was demonstrated. According to IRAE simplicity, reliability, fast and easy to implement, it was successfully applied to the determination of Ca, Cu, Fe, K, Mg, Mn, P and Zn in agrifood samples.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
Green tools  
dc.subject
Infrared assisted extraction  
dc.subject
Ultrasound assisted extraction  
dc.subject
Microwave induced plasma atomic emission spectrometry  
dc.subject
Multivariate optimization  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Assessing the greenness of optimized ultrasound and infrared assisted extraction through analytical metrics  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2024-04-09T12:04:40Z  
dc.journal.volume
5  
dc.journal.pagination
1-34  
dc.journal.pais
Países Bajos  
dc.description.fil
Fil: Cora Jofré, Florencia. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina  
dc.description.fil
Fil: Azcarate, Silvana Mariela. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina  
dc.description.fil
Fil: Camiña, José Manuel. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina  
dc.description.fil
Fil: Pacheco, Pablo Hugo. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Savio, Marianela. Consejo Nacional de Investigaciones Científicas y Técnicas. Instituto de Ciencias de la Tierra y Ambientales de La Pampa. Universidad Nacional de La Pampa. Facultad de Ciencias Exactas y Naturales. Instituto de Ciencias de la Tierra y Ambientales de La Pampa; Argentina  
dc.journal.title
Advances in Sample Preparation  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S2772582023000049?via%3Dihub  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1016/j.sampre.2023.100054