Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Una aproximación a las descargas por evapotranspiración del acuífero freático pampeano en la cuenca del arroyo del Azul (Llanura Pampeana)

Título: An approach to the evapotranspiration discharges of the pampeano aquifer in the del Azul basin (Pampean Plain)
Marcovecchio, RominaIcon ; Varni, Marcelo Raúl
Fecha de publicación: 12/2020
Editorial: Universidad Nacional de Rosario. Facultad de Ciencias Exactas, Ingeniería y Agrimensura. Centro Universitario Rosario de Investigaciones Hidroambientales
Revista: Cuadernos del Curiham
ISSN: 1514-2906
e-ISSN: 2683-8168
Idioma: Español
Tipo de recurso: Artículo publicado
Clasificación temática:
Oceanografía, Hidrología, Recursos Hídricos

Resumen

 
Se estudian las recargas mensuales totales, las descargas por flujo subterráneo a zonas de descarga y las pérdidas por evapotranspiración directa desde el nivel freático a partir de la variación diaria del nivel freático en una perforación somera en la zona llana de la cuenca del arroyo del Azul, ubicada en la llanura pampeana. Los niveles freáticos se registraron mediante un sensor de presión piezorresistivo. El acuífero freático analizado es el acuífero Pampeano. Los niveles freáticos variaron en el período analizado (2007-2018) entre 0,5 y 4 m de profundidad. Se ha encontrado que las descargas por evapotranspiración directa desde el nivel freático son una fracción relevante de la recarga total (42%). Las descargas por evapotranspiración directa son mayores en los meses cálidos, aunque la menor variabilidad interanaual se da en los meses fríos y en los meses cálidos. La mayor variabilidad se da en otoño y primavera. En el período 2007-2018 la recarga total anual promedio fue de 252 mm, la pérdida anual promedio de la recarga a la atmósfera fue de 105mm, con una desviación estándar de 25 mm y un coeficiente de variación de 0,24. Este porcentaje importante de la recarga total que se pierde por evapotranspiración directa hace que se deban considerar con especial atención los balances de agua en el suelo para estimar la recarga al acuífero (que no consideran esta pérdida) y explica ciertas incongruencias con los modelos de flujo de aguas subterráneas que exigían una disminución de la recarga en la zona más llana para posibilitar el ajuste de los niveles freáticos.
 
Total monthly recharges, discharges by groundwater flow to discharge zones and losses by direct evapotranspiration from the water table are studied from the daily variation of the water table level in a shallow well in the flat area of the Azul stream basin., located at the Pampean plain. The phreatic levels were recorded using a piezoresistive pressure sensor. The analyzed phreatic aquifer is the Pampeano aquifer. The phreatic levels varied in the period analyzed (2007-2018) between 0.5 and 4 m deep. Direct evapotranspiration discharges from the water table have been found to be a relevant fraction of the total recharge (42%). Direct evapotranspiration discharges are higher in warm months, although the least interannual variability occurs in cold and warm months. The greatest variability occurs in autumn and spring. In the period 2007-2018, the average annual total recharge was 252 mm, the average annual loss of recharge to the atmosphere was 105 mm, with a standard deviation of 25 mm and a coefficient of variation of 0.24. This important percentage of the total recharge that is lost by direct evapotranspiration means that the soil water balances must be considered with special attention to estimate the recharge to the aquifer (which does not consider this loss) and explains certain inconsistencies with the groundwater flow models. that required a decrease in recharge in the flattest area to enable the adjustment of the water table levels.
 
Palabras clave: RECARGA TOTAL AL ACUÍFERO FREÁTICO , DESCARGA POR FLUJO SUBTERRÁNEO , DESCARGA DIRECTA POR EVAPOTRANSPIRACIÓN
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 1.427Mb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/207865
URL: https://cuadernosdelcuriham.unr.edu.ar/index.php/CURIHAM/article/view/149
DOI: http://dx.doi.org/10.35305/curiham.v26i0.149
Colecciones
Articulos(CCT - TANDIL)
Articulos de CTRO CIENTIFICO TECNOLOGICO CONICET - TANDIL
Citación
Marcovecchio, Romina; Varni, Marcelo Raúl; Una aproximación a las descargas por evapotranspiración del acuífero freático pampeano en la cuenca del arroyo del Azul (Llanura Pampeana); Universidad Nacional de Rosario. Facultad de Ciencias Exactas, Ingeniería y Agrimensura. Centro Universitario Rosario de Investigaciones Hidroambientales; Cuadernos del Curiham; 26; 12-2020; 13-19
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES