Repositorio Institucional
Repositorio Institucional
CONICET Digital
  • Inicio
  • EXPLORAR
    • AUTORES
    • DISCIPLINAS
    • COMUNIDADES
  • Estadísticas
  • Novedades
    • Noticias
    • Boletines
  • Ayuda
    • General
    • Datos de investigación
  • Acerca de
    • CONICET Digital
    • Equipo
    • Red Federal
  • Contacto
JavaScript is disabled for your browser. Some features of this site may not work without it.
  • INFORMACIÓN GENERAL
  • RESUMEN
  • ESTADISTICAS
 
Artículo

Control Methods for Single-phase Voltage Supply with VSCs to Feed Nonlinear Loads in Rural Areas

Gil Gonzalez, Walter Julián; Bocanegra, Sara Yulieth; Serra, Federico MartinIcon ; Bueno López, Maximiliano; Magaldi, Guillermo LucianoIcon
Fecha de publicación: 12/2020
Editorial: Universidad Tecnológica de Bolivar
Revista: Transactions on Energy Systems and Engineering Applications
e-ISSN: 2745-0120
Idioma: Inglés
Tipo de recurso: Artículo publicado
Clasificación temática:
Ingeniería Eléctrica y Electrónica

Resumen

 
Este artículo aborda el problema de la generación de voltaje sinusoidal en cargas lineales utilizando un inversor de fuente de voltaje (VSI). La estructura port-Hamiltoniana en lazo abierto se utiliza para diseñar un controlador basado en pasividad con ganancias proporcionales-integrales (PI-PBC) con el fin de desarrollar la estrategia de control. La principal ventaja de utilizar controladores basados en pasividad corresponde a la posibilidad de garantizar la estabilidad asintótica transformando el problema de seguimiento de trayectoria en uno de control de regulación. Además del PI-PBC, se emplea un estimador de carga lineal basado en una formulación integral para determinar el valor de la conductancia equivalente en la carga, lo que reduce el número de sensores de corriente. Las validaciones numéricas demuestran que el voltaje sinusoidal proporcionado por el VSI a la carga tiene un error de seguimiento menor a 1 %, con distorsiones armónicas menores a 2.6 %, tanto para voltaje como para corrientes en la carga. Todas las simulaciones se realizaron en MATLAB/Simulink utilizando la biblioteca SimPowerSystems versión 2017 a.
 
This paper addresses the problem of sinusoidal voltage generation in linear loads using a voltage source inverter (VSI). The port-Hamiltonian structure in open-loop is used to design a passivity-based controller with proportional-integral gains (PI-PBC) in order to develop the control strategy. The main advantage of using passivity-based controllers corresponds to the possibility of guaranteeing asymptotic stability by transforming the trajectory tracking problem into a regulation control one. In addition to the PI-PBC, a linear load estimator is employed based on an integral formulation to determine the value of the equivalent conductance in the load, which reduces the number of current sensors. Numerical validations demonstrate that the sinusoidal voltage provided by the VSI to the load has a tracking error lower than 1 %, with harmonic distortions lower than 2.6 %, both for voltage and currents in the load. All the simulations were conducted in MATLAB/Simulink using the SimPowerSystems library version 2017a.
 
Palabras clave: LINEAR LOADS , PASSIVITY-BASED CONTROL , STABILITY ANALYSIS , VOLTAGE GENERATION , VOLTAGE SOURCE CONVERTERS
Ver el registro completo
 
Archivos asociados
Thumbnail
 
Tamaño: 392.2Kb
Formato: PDF
.
Descargar
Licencia
info:eu-repo/semantics/openAccess Excepto donde se diga explícitamente, este item se publica bajo la siguiente descripción: Creative Commons Attribution-NonCommercial-ShareAlike 2.5 Unported (CC BY-NC-SA 2.5)
Identificadores
URI: http://hdl.handle.net/11336/144254
URL: https://revistas.utb.edu.co/index.php/tesea/article/view/411
DOI: https://doi.org/10.32397/tesea.vol1.n1.3
Colecciones
Articulos(INTEQUI)
Articulos de INST. DE INVEST. EN TECNOLOGIA QUIMICA
Citación
Gil Gonzalez, Walter Julián; Bocanegra, Sara Yulieth; Serra, Federico Martin; Bueno López, Maximiliano; Magaldi, Guillermo Luciano; Control Methods for Single-phase Voltage Supply with VSCs to Feed Nonlinear Loads in Rural Areas; Universidad Tecnológica de Bolivar; Transactions on Energy Systems and Engineering Applications; 1; 1; 12-2020; 33-47
Compartir
Altmétricas
 

Enviar por e-mail
Separar cada destinatario (hasta 5) con punto y coma.
  • Facebook
  • X Conicet Digital
  • Instagram
  • YouTube
  • Sound Cloud
  • LinkedIn

Los contenidos del CONICET están licenciados bajo Creative Commons Reconocimiento 2.5 Argentina License

https://www.conicet.gov.ar/ - CONICET

Inicio

Explorar

  • Autores
  • Disciplinas
  • Comunidades

Estadísticas

Novedades

  • Noticias
  • Boletines

Ayuda

Acerca de

  • CONICET Digital
  • Equipo
  • Red Federal

Contacto

Godoy Cruz 2290 (C1425FQB) CABA – República Argentina – Tel: +5411 4899-5400 repositorio@conicet.gov.ar
TÉRMINOS Y CONDICIONES