Mostrar el registro sencillo del ítem

dc.contributor.author
Lancioni, Carlina  
dc.contributor.author
Aspromonte, Juan  
dc.contributor.author
Tascon, Marcos  
dc.contributor.author
Gagliardi, Leonardo Gabriel  
dc.date.available
2021-08-31T18:53:44Z  
dc.date.issued
2021-05-24  
dc.identifier.citation
Lancioni, Carlina; Aspromonte, Juan; Tascon, Marcos; Gagliardi, Leonardo Gabriel; Development of a background electrolyte for the determination of inorganic cations in high ionic strength samples by capillary electrophoresis with indirect UV-absorption detection; Elsevier Science; Journal of Chromatography - A; 1645; 24-5-2021; 1-33  
dc.identifier.issn
0021-9673  
dc.identifier.uri
http://hdl.handle.net/11336/139358  
dc.description.abstract
In this study, a background electrolyte capable to separate and quantify inorganic cations in high ionic strength samples by UV-absorption indirect detection was designed. In this regard, the four most abundant monovalent and divalent cations in earth crust (K+ , Na+ , Ca+2, Mg+2) were selected as model compounds. A group of small carboxylic acids and, several toluidines and pyridines were evaluated as mild strength complexing agents and chromophoric probes, respectively. The optimized background electrolyte was composed of 200 mM 2,4,6-trimethylpyridine as the chromophoric probe, 250 mM lactic acid as the weak complexing agent and pH buffering reagent (adjusted to pH 4.5), and 5 % v/v methanol as organic solvent modifier. Based on a minimum number of components, it provided outstanding separation performance in less than 4 min in a wide linear dynamic range (10 - 2500 µg∙mL-1 ). Performances were contrasted against a reference method based on conductometric detection. Furthermore, studies of separation efficiency and peak shape were carried out at different analyte concentrations in high electric conductivity solutions. The herein developed method demonstrated exceptional features in terms of limits of detection (~10 µg∙mL-1 ), resolution, speed of analysis, sensitivity and peak capacity in high electric conductivity samples. Moreover, the method was successfully applied to high ionic strength samples such as rock digest, sea water, soy sauce and isotonic drinks.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Elsevier Science  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-nd/2.5/ar/  
dc.subject
CAPILLARY ELECTROPHORESIS  
dc.subject
HIGH IONIC STRENGTH SAMPLES  
dc.subject
INDIRECT UV-ABSORPTION DETECTION  
dc.subject
INORGANIC CATIONS  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
Development of a background electrolyte for the determination of inorganic cations in high ionic strength samples by capillary electrophoresis with indirect UV-absorption detection  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2021-08-13T16:49:40Z  
dc.journal.volume
1645  
dc.journal.pagination
1-33  
dc.journal.pais
Países Bajos  
dc.journal.ciudad
Amsterdam  
dc.description.fil
Fil: Lancioni, Carlina. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina  
dc.description.fil
Fil: Aspromonte, Juan. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Katholikie Universiteit Leuven; Bélgica. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina  
dc.description.fil
Fil: Tascon, Marcos. Universidad Nacional de San Martín. Instituto de Investigación e Ingeniería Ambiental. - Consejo Nacional de Investigaciones Científicas y Técnicas. Oficina de Coordinación Administrativa Parque Centenario. Instituto de Investigación e Ingeniería Ambiental; Argentina  
dc.description.fil
Fil: Gagliardi, Leonardo Gabriel. Universidad Nacional de la Plata. Facultad de Cs.exactas. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos. - Comision de Investigaciones Cientificas de la Provincia de Buenos Aires. Laboratorio de Investigacion y Desarrollo de Metodos Analiticos.; Argentina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - La Plata; Argentina  
dc.journal.title
Journal of Chromatography - A  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/pii/S0021967321002156  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.chroma.2021.462091