Mostrar el registro sencillo del ítem

dc.contributor.author
Santibáñez, M.  
dc.contributor.author
Vásquez, M.  
dc.contributor.author
Silva, A.  
dc.contributor.author
Malano, Francisco Mauricio  
dc.contributor.author
Valente, Mauro Andres  
dc.contributor.author
Figueroa, R. G.  
dc.date.available
2021-01-29T18:52:12Z  
dc.date.issued
2019-09  
dc.identifier.citation
Santibáñez, M.; Vásquez, M.; Silva, A.; Malano, Francisco Mauricio; Valente, Mauro Andres; et al.; A high-sensitivity and low dose energy-dispersive X-ray fluorescence system for identification of gadolium accumulations in planar X-ray fluorescence images; Pergamon-Elsevier Science Ltd; Applied Radiation and Isotopes; 151; 9-2019; 46-51  
dc.identifier.issn
0969-8043  
dc.identifier.uri
http://hdl.handle.net/11336/124266  
dc.description.abstract
A new technique, based on in-vivo energy dispersive X-ray fluorescence (EDXRF), has been developed to gadolinium (Gd)concentrations identification in planar X-ray fluorescence (XRF)images. Higher signal-to-noise (SNR)ratios while keeping a low radiation dose were achieved. Experimental validation was performed using tissue equivalent phantoms under two different data acquisition criteria. The first criteria consisted on acquiring the energy spectra from different experimental narrow spectrum beam (FWHM = 2.5 keV)with peak central energy above the L edge energy and determining the spectrum which producing Lowest-Limit-of-Detection (Lowest-LoD)for a specific acquisition time. This also provided the minimum dose expected under the condition of minimum irradiation time. The second criteria consisted on measuring the surface dose required to obtain a specific LoD by different narrow spectrum beam, providing the Lowest-Dose setting. Surface (2D)Gd-doped tissue-equivalent phantoms scanning were performed according to optimized scenarios: Lowest-LoD setting (obtaining to central energy of 10.9 keV)and Lowest-Dose setting (obtaining to central energy 12.9 keV). 625 pixel images were acquired in two different conditions: a pre-defined time (5 s)per pixel was set in the first approach, whereas a pre-defined total surface dose (4 mGy)was set to the second approach. According to the results obtained for the first approach, a 58 times reduction was observed when comparing SNR between the Lowest-LoD and Lowest-Dose settings. On the other hand, for the second approach pre-defining total dose during the whole examination, the best SNR was obtained for the Lowest-Dose configuration exhibiting a 42% of increment respecting to the Lowest-LoD configuration and 47 times higher when compared with the limit case of no optimization.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Pergamon-Elsevier Science Ltd  
dc.rights
info:eu-repo/semantics/restrictedAccess  
dc.rights.uri
https://creativecommons.org/licenses/by-nc-sa/2.5/ar/  
dc.subject
IN VIVO 2D EDXRF IMAGING  
dc.subject
NON-INVASIVE IN-PHANTOM GADOLINIUM MAPPING  
dc.subject.classification
Física Atómica, Molecular y Química  
dc.subject.classification
Ciencias Físicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
A high-sensitivity and low dose energy-dispersive X-ray fluorescence system for identification of gadolium accumulations in planar X-ray fluorescence images  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-11-19T21:27:11Z  
dc.journal.volume
151  
dc.journal.pagination
46-51  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Santibáñez, M.. Universidad de La Frontera; Chile  
dc.description.fil
Fil: Vásquez, M.. Centro Oncológico Antofagasta; Chile  
dc.description.fil
Fil: Silva, A.. Universidad de La Frontera; Chile  
dc.description.fil
Fil: Malano, Francisco Mauricio. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad de La Frontera; Chile  
dc.description.fil
Fil: Valente, Mauro Andres. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - Córdoba. Instituto de Física Enrique Gaviola. Universidad Nacional de Córdoba. Instituto de Física Enrique Gaviola; Argentina. Universidad de La Frontera; Chile  
dc.description.fil
Fil: Figueroa, R. G.. Universidad de La Frontera; Chile  
dc.journal.title
Applied Radiation and Isotopes  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.apradiso.2019.05.007  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S096980431930260X