Mostrar el registro sencillo del ítem

dc.contributor.author
Talio, María Carolina  
dc.contributor.author
Feresin, Valentina  
dc.contributor.author
Muñoz, Vanesa Alejandra  
dc.contributor.author
Acosta, Mariano  
dc.contributor.author
Fernandez, Liliana Patricia  
dc.date.available
2020-09-02T14:44:16Z  
dc.date.issued
2019-09  
dc.identifier.citation
Talio, María Carolina; Feresin, Valentina; Muñoz, Vanesa Alejandra; Acosta, Mariano; Fernandez, Liliana Patricia; New Analytical Methodology for Sb(III) Traces Quantification as Emergent Contaminant in Drinks Packaged PET Samples by Solid Surface Fluorescence; Scientific Research Publishing; American Journal of Analytical Chemistry; 10; 9; 9-2019; 377-393  
dc.identifier.issn
2156-8278  
dc.identifier.uri
http://hdl.handle.net/11336/113015  
dc.description.abstract
Emerging contaminants constitute a set of substances that are released into the environment for which regulations are currently not established for their environmental monitoring, being antimony one of them. A new methodology for Sb(III) traces monitoring by solid surface fluorescence is proposed. The metal was complexed with alizarine (Az) as fluorosphore reagent in alcaline medium in presence of the bile salt sodium cholate. To isolate the analyte of matrix constituents, a preconcentration/separation strategy on filter paper was introduced prior to determination step. The solid surface fluorescence was measured λem = 450 nm and λexc = 363 nm using a solid sampler holder. Under optimal conditions, the limits of detection and quantification of proposed methodology were 0.08 and 0.24 μg·L-1, respectively, showing a linear range from 0.24 to 304.4 μg·L-1 with good sensitivity and adequate selectivity. It was applied to the Sb(III) traces determination present in drinking water and beverages samples packaged in polyethylene terephthalate (PET) bottles widely consumed in Argentina. The combination of a preconcentration step on common filter paper and the inherent sensitivity of photoluminescent methods have permitted to achieve sensitivity similar to atomic spectroscopies using a lower price instrument typical in control laboratories. Precision and accuracy were tested with excellent agreement. Results were truenessed by ETAAS with satisfactory concordance.  
dc.format
application/pdf  
dc.language.iso
eng  
dc.publisher
Scientific Research Publishing  
dc.rights
info:eu-repo/semantics/openAccess  
dc.rights.uri
https://creativecommons.org/licenses/by/2.5/ar/  
dc.subject
EMERGING CONTAMINANTS  
dc.subject
ANTIMONY TRACES  
dc.subject
ALIZARINE  
dc.subject
SOLID SURFACE FLUORESCENCE  
dc.subject
WATERS AND BEVERAGES  
dc.subject.classification
Química Analítica  
dc.subject.classification
Ciencias Químicas  
dc.subject.classification
CIENCIAS NATURALES Y EXACTAS  
dc.title
New Analytical Methodology for Sb(III) Traces Quantification as Emergent Contaminant in Drinks Packaged PET Samples by Solid Surface Fluorescence  
dc.type
info:eu-repo/semantics/article  
dc.type
info:ar-repo/semantics/artículo  
dc.type
info:eu-repo/semantics/publishedVersion  
dc.date.updated
2020-04-23T19:22:43Z  
dc.journal.volume
10  
dc.journal.number
9  
dc.journal.pagination
377-393  
dc.journal.pais
Estados Unidos  
dc.description.fil
Fil: Talio, María Carolina. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Feresin, Valentina. Universidad Nacional de San Luis; Argentina  
dc.description.fil
Fil: Muñoz, Vanesa Alejandra. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Acosta, Mariano. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.description.fil
Fil: Fernandez, Liliana Patricia. Consejo Nacional de Investigaciones Científicas y Técnicas. Centro Científico Tecnológico Conicet - San Luis. Instituto de Química de San Luis. Universidad Nacional de San Luis. Facultad de Química, Bioquímica y Farmacia. Instituto de Química de San Luis; Argentina  
dc.journal.title
American Journal of Analytical Chemistry  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/url/https://www.scirp.org/journal/ajac  
dc.relation.alternativeid
info:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.4236/ajac.2019.109026